Mercdes Trucks HZR and ZHE Fault Codes

On this page are presented list of fault codes for heater of Merecdes-Benz ActrosAxorAtego

List of DTCs of the Heating Control Unit (HZR)

0101 Internal sensor has a short to ground
0103 Internal sensor has a short to positive or open
0201 outdoor sensor has a short to ground
0203 The external sensor has a short to positive or open circuit.
0301 Heat exchanger sensor has a short to ground
0303 The heat exchanger sensor has a short to positive or open
0402 The heating valve has a short to ground.
0404 The heating valve has a short to positive or open
0501 Evaporator sensor short circuit to ground
0503 Evaporator sensor has a short to positive or open
0604 Compressor coupling has a short to positive or open

List of trouble codes for the auxiliary heater control unit (ZHE)

0000 control unit malfunction
0001 Malfunction of the control unit, internal temperature sensor
0100 Autonomous heater does not start
0104 Lock work after unsuccessful start
0200 flame break occurs again
0301 Overvoltage
0302 Low Voltage
0400 Premature Flame Detection
0501 Flame sensor short circuit
0502 Open in flame sensor circuit
0601 Temperature sensor short circuit
0602 Open in temperature sensor circuit
0701 metering pump short circuit
0702 Open circuit in metering pump
0801 Fan Motor Short Circuit
0802 Open in fan motor circuit
0803 Incorrect fan motor speed
0901 Glow pin short
0902 Open circuit in the filament pin chain
1000 Overheating autonomous heater
1004 Too many times overheating or excessive control has occurred (blocking work)
1101 Short circuit water pump
1102 Open in water pump circuit
1201 Setpoint Sensor Short Circuit
1202 Open circuit in the setpoint sensor circuit
1301 Overheating sensor has a short circuit.
1302 Overheating sensor has a break.
1303 Overheating sensor out of tolerance / operation range (Detection of excess control)
1401 Connection of a relay to a water pump has a short circuit.
1501 Short circuit on the connection of external components
1601 Relay connection for external fan has short circuit
1620 Relay connection for external fan is open
1701 Fan excitation for switching water circuits has a short circuit.
1702 Fan excitation for switching water circuits has an open circuit.