International Trucks Diagnostics Trouble Codes (DTCs)

International Trucks Fault Codes List (DTCs) for Model: 3200, 4100, 4300, 4400, 7300, 7400, 7500, 7600, 7700, 8500, 8600,
BE 200, CE Bus, CXT, DuraStar, LoneStar, MXT, ProStar, RXT, TranStar, WorkStar

DISPLAYING DIAGNOSTIC TROUBLE CODES

The ability to display diagnostic trouble codes (DTC) is an optional feature. Codes may be displayed on either the gauge cluster or an optional vehicle information display (VID). The vehicle must be equipped with the option to display codes in both cases. Codes will not be displayed on the gauge cluster if the vehicle is equipped with the VID.

 VEHICLES EQUIPPED WITH OPTION TO DISPLAY CODES

 Displaying Codes on the Gauge Cluster (Non-VID equipped vehicles)

To display codes on vehicles not equipped with a VID:

  1. Set the parking brake.
  2. Turn the key switch to the ACCESSORY position to view only previously active codes. Turn the key switch to the IGNITION position to view both active and previously active codes.
  3. Momentarily press the Cruise “ON” switch and the Cruise “Resume” switch at the same time.

A gauge sweep will be performed on the gauges. The gauge cluster will then display the following information for 5 seconds:

  • Software Rev: XXX
  • Hardware Rev: XXX
  • Active Faults: XXX
  • Total Faults: XXX

NOTE – The gauge cluster will only display “Software Rev” and “Hardware Rev” for 5 seconds followed by the message “Diagnostic Trouble Codes are not available” if the vehicle is not equipped with the option to display codes.

If faults are present, the gauge cluster display will show each diagnostic trouble code for 10 seconds and then automatically scroll to the next entry and continue to cycle through the faults. Once all faults have been displayed the number of faults will be displayed again, then the cycle will repeat. To manually cycle through the fault list press and release the cluster display selector button. The following information will be displayed for each fault:

SPN: XXXX FMI: XX
Active
OC: XXX SA: XXX

SPN: XXXX FMI: XX
Previously Active OC: XXX SA: XXX

NOTE – Turning the key switch off, turning the key switch to the CRANK position, or releasing the park brake will take the gauge cluster out of the diagnostic mode.

Displaying Codes on the VID (if equipped)

The VID can be used to display all diagnostic trouble codes (DTC) on the vehicle. Suspect parameter number (SPN), failure mode indicator (FMI) and occurrence count numbers are listed. Source addresses and DTC descriptions are presented in plain text.

NOTE – The VID will display “Not Available” if a DTC description is not available for a particular fault.

Displaying codes will only be allowed if all of the following conditions are true:

• The key switch is in the IGNITION position.
• AND displaying codes is allowed due to vehicle orderable options
• AND the programmable parameter “Diagnostics” is enabled using Diamond Logic® Builder (DLB).
• The vehicle is not moving (the Vehicle Speed is equal to zero).
• The feature is not password protected to prevent unauthorized access. Refer to the Vehicle Information Display Owner’s Manual for more information.

Perform the following steps if all of the above conditions are met:

1. Go to the main menu screen

NOTE – The following selections will not be available if the vehicle is not equipped with the option to display codes.

2. Select “DIAGNOSTIC CODES”

3. Select “ACTIVE” or “INACTIVE”. The VID may initiate a password prompt if the VID has been password protected. Refer to the Vehicle Information Display Owner’s Manual for more information.

The VID will indicate “NO FAULT DETECTED” if faults are not found. Scroll through the list of faults if faults are present.
The following information will be displayed for each fault: SPN : FMI OC
SA
DTC Description

CLEARING DIAGNOSTIC TROUBLE CODES

Previously active diagnostic trouble codes can only be cleared by a service tool, such as Diamond Logic® Builder (DLB). Some previously active codes may not be cleared by this method.

DEFINITIONS

  • “SPN” represents the Suspect Parameter Number. This number identif es the item for which diagnostics are being reported.
  • FMI” is the Failure Mode Indicator. This number represents the type of failure detected. Refer to Failure Mode Indicators (FMI) below for more information.
  • Active” or “Previously Active” will be displayed to identify whether a fault is currently active or if the fault was previously active.
  • OC” is the Occurrence Count. This number represents the number of times a fault has gone from previously active to active.
  • “SA” is the Source Address. This number identif es the module reporting the fault. Refer to Source Addresses (SA) for more information.

FAILURE MODE INDICATORS (FMI)

FMI=0 – Data Valid But Above Normal Operational Range – Most Severe Level
FMI=1 – Data Valid But Below Normal Operational Range – Most Severe Level
FMI=2 – Data Erratic, Intermittent Or Incorrect
FMI=3 – Voltage Above Normal, Or Shorted To High Source
FMI=4 – Voltage Below Normal, Or Shorted To Low Source
FMI=5 – Current Below Normal Or Open Circuit
FMI=6 – Current Above Normal Or Grounded Circuit
FMI=7 – Mechanical System Not Responding Or Out Of Adjustment
FMI=8 – Abnormal Frequency Or Pulse Width Or Period
FMI=9 – Abnormal Update Rate
FMI=10 – Abnormal Rate Of Change
FMI=11 – Root Cause Not Known
FMI=12 – Bad Intelligent Device Or Component
FMI=13 – Out Of Calibration
FMI=14 – Special Instructions
FMI=15 – Data Valid But Above Normal Operating Range – Least Severe Level
FMI=16 – Data Valid But Above Normal Operating Range – Moderately Severe Level
FMI=17 – Data Valid But Below Normal Operating Range – Least Severe Level
FMI=18 – Data Valid But Below Normal Operating Range – Moderately Severe Level
FMI=19 – Received Network Data In Error
FMI=20 – Data Drifted High
FMI=21 – Data Drifted Low
FMI=31 – Condition Exists

SOURCE ADDRESSES (SA)

NOTE – The available source addresses will vary depending on each vehicle configuration.

NOTE – Diagnostic Trouble Codes listed in this document are Body Controller, Auxiliary Gauge Switch Pack, Secondary Instrument Cluster, Instrument Cluster, Rear HVAC Module, and Compass Module.

DIAGNOSTIC TROUBLE CODE (DTC) LIST

SA SPN DTC Description FMI  Message Cause Comments Pins
33 116 Brake Application Pressure 0 Brake Application Pressure Sensor

reading above normal range

Brake Application Sensor Shorted High or

faulty sensor system

1600-B14
33

 

 

33

116

 

 

158

Brake Application Pressure

 

 

Battery Potential (Voltage), Switched

1

 

 

2

Brake Application Pressure Sensor reading below normal range

 

Key State Ignition Signal Error

Brake Application Sensor Short To Ground or Open Circuit or faulty sensor system

Open in Ignition Signal Input Circuit To BC

1600-B14

 

 

1600-A16

33

 

 

33

168

 

 

168

Electrical Potential (Voltage)

 

 

Electrical Potential (Voltage)

2

 

 

3

Comm. fault from ESC/BC to PP3.

 

 

DC Module Overvoltage condition on

Datalink interrupted between ESC and Powerpack.

 

An Over Voltage Condition in the DC

The Power Pack E Module has stopped receiving heart beet message from the ESC/BC.

A High Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

3

Vehicle DC Bus.

 

 

AC Module Overvoltage condition on

regulator (Vehicle Battery Bus).

 

 

An Over Voltage Condition in the AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

A high Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

4

High Voltage DC Bus.

 

 

DC Module Undervoltage condition

module (Inverter High Voltage Bus).

 

 

An Under Voltage Condition in the DC

occurred and the source of the fault is the AC module (inverter high voltage bus).

A Low Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

4

on Vehicle DC Bus.

 

 

AC Module Undervoltage condition

regulator (Vehicle Battery Bus).

 

 

An Under Voltage Condition in the AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

A low Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

6

on High Voltage DC Bus.

 

 

AC Module has shutdown due to

module (Inverter High Voltage Bus).

 

 

A Surge may have occurred for a while in

occurred and the source of the fault is the AC module (inverter high voltage bus).

An Overload condition has been

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

8

overload condition.

 

 

Phase missing fault/alternator fault.

the Vehicle AC bus for a long time (The inverter supplies additional current to the load).

One or more of the three phase wire from

detected in the AC module and the Vehicle AC bus is shutdown.

 

One or more of the three phase

 

 

 

 

33

 

 

 

 

168

 

 

 

 

Electrical Potential (Voltage)

 

 

 

 

16

 

 

 

 

DC module over temperature

the Dynamic Alternator to the Power Pack E module may be disconnected.

 

 

An overcurrent condition in the Vehicle DC

wires from the alternator is disconnected. The Power Pack system is shutdown and requires an ignition cycle.

An Over Temperature fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

16

condition.

 

 

AC module over temperature

Bus might have caused an over temperature.

 

An overcurrent condition in the Vehicle AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

An Over temperature fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

17

condition.

 

 

PPE3 Fuse Open.

Bus might have caused an over temperature.

 

Load exceeded rating.

occurred and the source of the fault is the AC module (inverter high voltage bus).

PPE3 module Fuse is Open.

33

 

 

33

175

 

 

175

Engine Oil Temperature 1

 

 

Engine Oil Temperature 1

0

 

 

1

Engine Oil Temp Sensor reading above normal range

 

Engine Oil Temp Sensor reading

Engine Oil Temperature Sensor Shorted High or Open Circuit or faulty sensor system

Engine Oil Temperature Sensor Short to

1600-B6

 

 

1600-B6

 

33

 

177

 

Transmission Oil Temperature

 

0

below normal range

Transmission Oil Temperature

Ground or faulty sensor system

Transmission Oil Temperature Sensor

 

1600-B7

 

 

33

 

 

177

 

 

Transmission Oil Temperature

 

 

1

Sensor reading above normal range

 

Transmission Oil Temperature

Shorted High or Open Circuit or faulty sensor system

Transmission Oil Temperature Sensor

 

 

1600-B7

Sensor reading below normal range Short to Ground or faulty sensor system
33

 

 

33

247

 

 

564

Total Engine Hours

 

 

Differential Lock State – Central

9

 

 

5

Engine Total Hours Not Received

 

 

Transfer Case Lock Under Current

The Engine Control Module did send the Total Engine Hours or possible Data Link failure

Current below normal or open circuit

 

 

 

Not available

 

 

 

Not

 

33

 

564

 

Differential Lock State – Central

 

6

Or Open Circuit

Transfer Case Lock Relay Over

 

Current above normal or grounded circuit

 

Not available

available

Not

 

33

 

566

 

Differential Lock State – Central Rear

 

5

Current

Power Divider Lock Relay Under

 

Open Circuit in Power Divider Lock Circuit

available
 

33

 

566

 

Differential Lock State – Central Rear

 

6

Current Or Open Circuit

Power Divider Lock Relay Over

 

Short To Ground in Power Divider Lock

 

33

 

567

 

Differential Lock State – Front Axle 1

 

5

Current

Forward Axle 1 Diff lock air solenoid

Circuit

Current below normal or open circuit

 

Not available

 

Not

 

 

 

33

 

 

 

567

 

 

 

Differential Lock State – Front Axle 1

 

 

 

6

output undercurrent or open circuit

 

 

Forward Axle 1 Diff lock air solenoid

 

 

 

Current above normal or grounded circuit

 

 

 

Not available

available

 

 

Not

 

 

 

33

 

 

 

569

 

 

 

Differential Lock State – Rear Axle 1

 

 

 

5

output overcurrent

 

 

Forward Rear Diff Lock Relay Under

 

 

 

Open Circuit in Forward Rear Diff Lock

available
Current Or Open Circuit Circuit
33 569 Differential Lock State – Rear Axle 1 6 Forward Rear Diff Lock Relay Over Current Short To Ground in Forward Rear Diff Lock Circuit
33

 

33

570

 

570

Differential Lock State – Rear Axle 2

 

Differential Lock State – Rear Axle 2

5

 

6

Rear Rear Diff Lock Relay Under Current Or Open Circuit

Rear Rear Diff Lock Relay Over

Open Circuit in Rear Rear Diff Lock Circuit

 

Short To Ground in Rear Rear Diff Lock

 

33

 

571

 

Retarder Enable – Brake Assist

 

2

Current

Retarder Enable – Brake Assist

Circuit

Data erratic, intermittent or incorrect

 

33

 

576

Switch

ASR Off-road Switch

 

2

On/Off switch failure

Traction Disable panel mounted

 

Data erratic, intermittent or incorrect

 

33

 

577

 

ASR “Hill Holder” Switch

 

2

switch is in an invalid position

HSA Disable Switch error

 

Fault in HSA Disable Switch

 

Not available

 

Not

 

33

 

596

 

Cruise Control Enable Switch

 

0

 

Cruise Control Switch reading above

 

Shorted High or Open in Cruise Control

available

1600-B16

 

33

 

596

 

Cruise Control Enable Switch

 

1

normal range

Cruise Control Switch reading below

Switches Circuit

Short To Ground in Cruise Control

 

1600-B16

normal range Switches Circuit

International Trucks Diagnostics Trouble Codes (DTCs)

33 116 Brake Application Pressure 0 Brake Application Pressure Sensor

reading above normal range

Brake Application Sensor Shorted High or

faulty sensor system

1600-B14
33

 

 

33

116

 

 

158

Brake Application Pressure

 

 

Battery Potential (Voltage), Switched

1

 

 

2

Brake Application Pressure Sensor reading below normal range

 

Key State Ignition Signal Error

Brake Application Sensor Short To Ground or Open Circuit or faulty sensor system

Open in Ignition Signal Input Circuit To BC

1600-B14

 

 

1600-A16

33

 

 

33

168

 

 

168

Electrical Potential (Voltage)

 

 

Electrical Potential (Voltage)

2

 

 

3

Comm. fault from ESC/BC to PP3.

 

 

DC Module Overvoltage condition on

Datalink interrupted between ESC and Powerpack.

 

An Over Voltage Condition in the DC

The Power Pack E Module has stopped receiving heart beet message from the ESC/BC.

A High Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

3

Vehicle DC Bus.

 

 

AC Module Overvoltage condition on

regulator (Vehicle Battery Bus).

 

 

An Over Voltage Condition in the AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

A high Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

4

High Voltage DC Bus.

 

 

DC Module Undervoltage condition

module (Inverter High Voltage Bus).

 

 

An Under Voltage Condition in the DC

occurred and the source of the fault is the AC module (inverter high voltage bus).

A Low Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

4

on Vehicle DC Bus.

 

 

AC Module Undervoltage condition

regulator (Vehicle Battery Bus).

 

 

An Under Voltage Condition in the AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

A low Battery Cutout fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

6

on High Voltage DC Bus.

 

 

AC Module has shutdown due to

module (Inverter High Voltage Bus).

 

 

A Surge may have occurred for a while in

occurred and the source of the fault is the AC module (inverter high voltage bus).

An Overload condition has been

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

8

overload condition.

 

 

Phase missing fault/alternator fault.

the Vehicle AC bus for a long time (The inverter supplies additional current to the load).

One or more of the three phase wire from

detected in the AC module and the Vehicle AC bus is shutdown.

 

One or more of the three phase

 

 

 

 

33

 

 

 

 

168

 

 

 

 

Electrical Potential (Voltage)

 

 

 

 

16

 

 

 

 

DC module over temperature

the Dynamic Alternator to the Power Pack E module may be disconnected.

 

 

An overcurrent condition in the Vehicle DC

wires from the alternator is disconnected. The Power Pack system is shutdown and requires an ignition cycle.

An Over Temperature fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

16

condition.

 

 

AC module over temperature

Bus might have caused an over temperature.

 

An overcurrent condition in the Vehicle AC

occurred and the source of the fault is the DC regulator (Vehicle Battery Bus).

An Over temperature fault has

 

 

 

33

 

 

 

168

 

 

 

Electrical Potential (Voltage)

 

 

 

17

condition.

 

 

PPE3 Fuse Open.

Bus might have caused an over temperature.

 

Load exceeded rating.

occurred and the source of the fault is the AC module (inverter high voltage bus).

PPE3 module Fuse is Open.

33

 

 

33

175

 

 

175

Engine Oil Temperature 1

 

 

Engine Oil Temperature 1

0

 

 

1

Engine Oil Temp Sensor reading above normal range

 

Engine Oil Temp Sensor reading

Engine Oil Temperature Sensor Shorted High or Open Circuit or faulty sensor system

Engine Oil Temperature Sensor Short to

1600-B6

 

 

1600-B6

 

33

 

177

 

Transmission Oil Temperature

 

0

below normal range

Transmission Oil Temperature

Ground or faulty sensor system

Transmission Oil Temperature Sensor

 

1600-B7

 

 

33

 

 

177

 

 

Transmission Oil Temperature

 

 

1

Sensor reading above normal range

 

Transmission Oil Temperature

Shorted High or Open Circuit or faulty sensor system

Transmission Oil Temperature Sensor

 

 

1600-B7

Sensor reading below normal range Short to Ground or faulty sensor system
33

 

 

33

247

 

 

564

Total Engine Hours

 

 

Differential Lock State – Central

9

 

 

5

Engine Total Hours Not Received

 

 

Transfer Case Lock Under Current

The Engine Control Module did send the Total Engine Hours or possible Data Link failure

Current below normal or open circuit

 

 

 

Not available

 

 

 

Not

 

33

 

564

 

Differential Lock State – Central

 

6

Or Open Circuit

Transfer Case Lock Relay Over

 

Current above normal or grounded circuit

 

Not available

available

Not

 

33

 

566

 

Differential Lock State – Central Rear

 

5

Current

Power Divider Lock Relay Under

 

Open Circuit in Power Divider Lock Circuit

available
 

33

 

566

 

Differential Lock State – Central Rear

 

6

Current Or Open Circuit

Power Divider Lock Relay Over

 

Short To Ground in Power Divider Lock

 

33

 

567

 

Differential Lock State – Front Axle 1

 

5

Current

Forward Axle 1 Diff lock air solenoid

Circuit

Current below normal or open circuit

 

Not available

 

Not

 

 

 

33

 

 

 

567

 

 

 

Differential Lock State – Front Axle 1

 

 

 

6

output undercurrent or open circuit

 

 

Forward Axle 1 Diff lock air solenoid

 

 

 

Current above normal or grounded circuit

 

 

 

Not available

available

 

 

Not

 

 

 

33

 

 

 

569

 

 

 

Differential Lock State – Rear Axle 1

 

 

 

5

output overcurrent

 

 

Forward Rear Diff Lock Relay Under

 

 

 

Open Circuit in Forward Rear Diff Lock

available
Current Or Open Circuit Circuit
33 569 Differential Lock State – Rear Axle 1 6 Forward Rear Diff Lock Relay Over Current Short To Ground in Forward Rear Diff Lock Circuit
33

 

33

570

 

570

Differential Lock State – Rear Axle 2

 

Differential Lock State – Rear Axle 2

5

 

6

Rear Rear Diff Lock Relay Under Current Or Open Circuit

Rear Rear Diff Lock Relay Over

Open Circuit in Rear Rear Diff Lock Circuit

 

Short To Ground in Rear Rear Diff Lock

 

33

 

571

 

Retarder Enable – Brake Assist

 

2

Current

Retarder Enable – Brake Assist

Circuit

Data erratic, intermittent or incorrect

 

33

 

576

Switch

ASR Off-road Switch

 

2

On/Off switch failure

Traction Disable panel mounted

 

Data erratic, intermittent or incorrect

 

33

 

577

 

ASR “Hill Holder” Switch

 

2

switch is in an invalid position

HSA Disable Switch error

 

Fault in HSA Disable Switch

 

Not available

 

Not

 

33

 

596

 

Cruise Control Enable Switch

 

0

 

Cruise Control Switch reading above

 

Shorted High or Open in Cruise Control

available

1600-B16

 

33

 

596

 

Cruise Control Enable Switch

 

1

normal range

Cruise Control Switch reading below

Switches Circuit

Short To Ground in Cruise Control

 

1600-B16

normal range Switches Circuit

 

 

33 1837 Convoy Driving Lamp Select 6 BO Drive Overcurrent Current above normal or grounded circuit Not available
33 1840 Rear Black Out Marker Select 6 BO Marker Overcurrent Current above normal or grounded circuit Not available
33 1841 Black Out Brake/Stop Lamp Select 6 BO Stop Overcurrent Current above normal or grounded circuit Not available
33

 

33

2000

 

2000

Source Address 0

 

Source Address 0

9

 

19

ECM Data Link Comm. Failure

 

PTC1 (PGN 64892) not Received

Faulty ECM or Drivetrain Data Link

 

ECM not Programmed for Aftertreatment,

from Engine Faulty ECM, or Faulty Drivetrain Data Link
33

 

33

2003

 

2011

Source Address 3

 

Source Address 11

9

 

9

TCM Data Link Comm. Failure

 

ABS Data Link Comm. Failure

Faulty TCM or Drivetrain Data Link

 

Faulty ABS Module or Drivetrain Data Link

 

33

 

2023

 

Gauge Cluster

 

9

 

EGC Data Link Comm. Failure

 

Faulty EGC or Drivetrain Data Link

 

33

 

2040

 

Auxiliary Switch Pack #1

 

9

 

AGSP #1 Data Link Comm. Failure

 

Abnormal update rate

 

33

 

2058

 

Source Address 58

 

9

 

Rear HVAC Data Link

 

Faulty Rear HVAC or Body Builder Data

 

33

 

2058

 

Source Address 58

 

14

Communication Failure

Rear HVAC Data Link

Link

Faulty Rear HVAC or Body Builder Data

 

33

 

2062

 

Source Address 62

 

9

Communication Failure

Meritor Wabco Brake Controller Data

Link

Faulty Meritor Wabco Brake Controller          Not available

 

33

 

2225

 

Remote Power Module #1 Fuse

 

9

Link Comm. Failure to BC

RPM #1 Data Link Comm. Failure

Module Data Link

Abnormal update rate

 

33

 

2225

 

Remote Power Module #1 Fuse

 

14

 

Remote Power Module #1 (address

 

Drivetrain J1939 data link, an improperly

225) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2226

 

2226

Remote Power Module #2 Fuse

 

Remote Power Module #2 Fuse

9

 

14

RPM #2 Data Link Comm. Failure

 

Remote Power Module #2 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

226) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2227

 

2227

Source Address 227

 

Source Address 227

9

 

14

RPM #3 Data Link Comm. Failure

 

Remote Power Module #3 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

227) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2228

 

2228

Remote Power Module #4 Fuse

 

Remote Power Module #4 Fuse

9

 

14

RPM #4 Data Link Comm. Failure

 

Remote Power Module #4 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

228) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2229

 

2229

Source Address 229

 

Source Address 229

9

 

14

RPM #5 Data Link Comm. Failure

 

Remote Power Module #5 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

229) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2230

 

2230

Source Address 230

 

Source Address 230

9

 

14

RPM #6 Data Link Comm. Failure

 

Remote Power Module #6 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

230) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2231

 

2231

Remote Power Module #7 Fuse

 

Remote Power Module #7 Fuse

9

 

14

RPM #7 Data Link Comm. Failure

 

Remote Power Module #7 (address

Abnormal update rate

 

Drivetrain J1939 data link, an improperly

231) has an address problem. addressed RPM module, or a missing RPM module that the BC is expecting
33

 

33

2233

 

2234

Source Address 233

 

Remote Air Solenoid #2 Fuse

9

 

9

Rear Driver Door Pod Data Link Comm. Failure

Rear Passenger Door Pod Data Link

Faulty Rear Driver Door Pod Module or Switch Data Link

Faulty Rear Passenger Door Pod Module

 

33

 

2236

 

Source Address 236

 

9

Comm. Failure

Driver Door Pod Data Link Comm.

or Switch Data Link

Faulty Driver Door Pod Module or Switch

 

33

 

2237

 

Source Address 237

 

9

Failure

Passenger Door Pod Data Link

Data Link

Faulty Passenger Door Pod Module or

 

33

 

2239

 

Source Address 239

 

9

Comm. Failure

HCM Data Link Comm. Failure

Switch Data Link

Faulty HCM or Drivetrain Data Link

 

33

 

2239

 

Source Address 239

 

14

 

HCM Address Conflict

 

Drivetrain J1939 data link, an improperly

 

 

33

 

 

2247

 

 

Source Address 247

 

 

9

 

 

Communication fault from PP3 to

addressed HCM, or a missing HCM that the BC is expecting

Private J1939 datalink problem (exceeded BC has failed to receive heartbeat

 

 

33

 

 

2361

 

 

Tractor Rear High Mounted Work

 

 

2

BC.

 

Work Light Switch Error

bandwidth).                                                           message from PowerPack E module.

Faulty Switch Actuator or Microswitch for

 

33

 

2362

Lights Command

Tractor Rear High Mounted Work

 

5

 

Work Light Undercurrent

Work Light Switch

Open in Work Light Circuit

 

33

 

2362

Lights

Tractor Rear High Mounted Work

 

6

 

Work Light Overcurrent

 

Short To Ground or Overload in Work

 

33

 

2368

Lights

Left Turn Signal Lights

 

5

 

Left Front Turn Lamp Undercurrent

Light Circuit

Open in Left Front Turn Signal Circuit

33 2368 Left Turn Signal Lights 6 Left Front Turn Lamp Overcurrent Short To Ground or Overload in Left Front
 

33

 

2370

 

Right Turn Signal Lights

 

5

 

Right Front Turn Lamp Undercurrent

Turn Signal Circuit

Open in Right Front Turn Signal Circuit

33 2370 Right Turn Signal Lights 6 Right Front Turn Lamp Overcurrent Short To Ground or Overload in Right
 

33

 

2372

 

Left Stop Light

 

5

 

Left Rear Turn Lamp Undercurrent

Front Turn Signal Circuit

Open in Left Rear Turn Signal Circuit

33 2372 Left Stop Light 6 Left Rear Turn Lamp Overcurrent Short To Ground or Overload in Left Rear
 

33

 

2374

 

Right Stop Light

 

5

 

Right Rear Turn Lamp Undercurrent

Turn Signal Circuit

Open in Right Rear Turn Signal Circuit

33 2374 Right Stop Light 6 Right Rear Turn Lamp Overcurrent Short To Ground or Overload in Right
33

 

33

881

 

881

Right Turn Lamp Circuit (Green)

 

Right Turn Lamp Circuit (Green)

5

 

6

Trailer Right Turn Lamp Relay Under

Current Or Open Circuit

Trailer Right Turn Lamp Relay Over

Open Circuit in Trailer Right Turn Lamp

Circuit

Short To Ground in Trailer Right Turn

1601-E15

 

1601-E15

 

33

 

882

 

Tail Lamp/License Plate Lamp

 

5

Current

Trailer License Plate Lamp Relay

Lamp Circuit

Open Circuit in Trailer License Plate

 

1601-E10

 

33

 

882

Circuit (Brown)

Tail Lamp/License Plate Lamp

 

6

Under Current Or Open Circuit

Trailer License Plate Lamp Relay

Lamp Circuit

Short To Ground in Trailer License Plate

 

1601-E10

 

33

 

973

Circuit (Brown)

Engine Retarder Selection

 

2

Over Current

Engine Retarder Level Selection

Lamp Circuit

Faulty Switch Actuator or Microswitch for

Switch Error Engine Retarder Level Select Switch
33 980 PTO Enable Switch 2 Engine PTO Switch Error Data erratic, intermittent or incorrect
33

 

33

986

 

1043

Requested Percent Fan Speed

 

Internal Sensor Voltage Supply

2

 

0

Engine Fan Switch Error

 

Bias Voltage reading above normal

Faulty Switch Actuator or Microswitch for Engine Fan Switch

Bias Voltage Circuit Shorted High

 

33

 

1043

 

Internal Sensor Voltage Supply

 

1

range

Bias Voltage reading below normal

 

Short To Ground in Bias Voltage Circuit

 

33

 

1079

 

Vref Sensor Supply Voltage

 

0

range

5V Sensor Supply Above Normal

 

Data valid but above normal operational

 

33

 

1079

 

Vref Sensor Supply Voltage

 

1

Range

5V Sensor Supply Below Normal

range – most severe level

Data valid but below normal operational

 

33

 

1081

 

Wait to Start Lamp

 

4

Range

Wait to Start Lamp

range – most severe level

Output shorted to ground

33 1081 Wait to Start Lamp 6 Wait to Start Lamp Output overheat
33

 

33

1087

 

1087

Service Brake Air Pressure Circuit #1

 

Service Brake Air Pressure Circuit #1

0

 

1

Primary Air Tank Sensor reading above normal range

Primary Air Tank Sensor reading

Primary Air Tank Sensor Shorted High or faulty sensor system

Primary Air Tank Sensor Short To Ground

1600-B2

 

1600-B2

below normal range or Open Circuit or faulty sensor system
33

 

33

1088

 

1088

Service Brake Air Pressure Circuit #2

 

Service Brake Air Pressure Circuit #2

0

 

1

Secondary Air Tank Sensor reading above normal range

Secondary Air Tank Sensor reading

Secondary Air Tank Sensor Shorted High or faulty sensor system

Secondary Air Tank Sensor Short To

1600-B3

 

1600-B3

 

 

33

 

 

1089

 

 

Auxiliary Equipment Supply Pressure

 

 

0

below normal range

 

Auxiliary Air Tank Sensor Reading

Ground or Open Circuit or faulty sensor system

Short to High in Air Pressure Auxiliary

 

 

1600-B2

 

33

 

1089

 

Auxiliary Equipment Supply Pressure

 

1

Above Normal

Auxiliary Air Tank Sensor Reading

Sensor Circuit

Short to Ground or Open in Air Pressure

 

1600-B2

 

33

 

1231

 

Body Address Claim/Message

 

9

Below Normal

J1939 Body Builder Data Link Lost

Auxiliary Sensor Circuit

Faulty BC or Bodybuilder Data Link

 

33

 

1231

Timeout

Body Address Claim/Message

 

14

 

Global Broadcast Messages, J1939,

Timeout proprietary, private bus (body builder) (address 255) has an unknown fault.
33

 

33

1238

 

1378

Traction Control Override Switch

 

Change Oil Lamp

2

 

4

ATC OFF-ROAD Switch Error

 

Change Oil Lamp

Faulty Switch Actuator or Micro switch for ATC OFF-ROAD Switch

Output shorted to ground

33 1378 Change Oil Lamp 6 Change Oil Lamp Output overheat
33

 

 

 

33

1382

 

 

 

1547

Fuel Filter (suction side) Differential Pressure

 

 

A/C Evaporator Temperature

14

 

 

 

0

The filter between the fuel pump and the fuel tank is plugged.

 

 

HVAC Inlet Temp Sensor reading

Heavy build up of particulate matter in the The detection has indicated a value fuel filter preventing fuel flow.               of 51 on the fuel filter signal which

indicates a severely restricted or plugged condition.

HVAC Refrigerant Inlet Temperature

 

 

 

 

1600-B5

 

 

33

 

 

1547

 

 

A/C Evaporator Temperature

 

 

1

above normal range

 

HVAC Inlet Temp Sensor reading

Sensor Shorted High or Open Circuit or faulty sensor system

HVAC Refrigerant Inlet Temperature

 

 

1600-B5

 

 

33

 

 

1548

 

 

HVAC Duct Temperature

 

 

0

below normal range

 

HVAC Outlet Temp Sensor reading

Sensor Short To Ground or faulty sensor system

HVAC Refrigerant Outlet Temperature

 

 

1600-B13

 

 

33

 

 

1548

 

 

HVAC Duct Temperature

 

 

1

above normal range

 

HVAC Outlet Temp Sensor reading

Sensor Shorted High or Open Circuit or faulty sensor system

HVAC Refrigerant Outlet Temperature

 

 

1600-B13

 

 

33

 

 

1552

 

 

Operator Input device for Cab

 

 

2

below normal range

 

HVAC Control Head Temperature

Sensor Short To Ground or faulty sensor system

HVAC Motor in Wrong Position or

 

33

 

1553

Climate Control

HVAC Blower Motor Speed

 

0

Mix DM1

HVAC Blower Speed Analog Input

Jammed

HVAC Blower Speed Control Shorted

 

1600-B15

 

 

33

 

 

1553

Adjustment

 

HVAC Blower Motor Speed

 

 

1

reading above normal range

 

HVAC Blower Speed Analog Input

High or Open Circuit or faulty sensor system

HVAC Blower Speed Control Short To

 

 

1600-B15

 

33

 

1660

Adjustment

Engine Automatic Start Alarm

 

5

reading below normal range

Remote Start Alarm Buzzer Relay

Ground or faulty sensor system

Open Circuit in Remote Start Alarm

 

33

 

1660

 

Engine Automatic Start Alarm

 

6

Under Current Or Open Circuit

Remote Start Alarm Buzzer Relay

Buzzer Circuit

Short To Ground in Remote Start Alarm

 

33

 

1709

 

Transmission Controller Power

 

5

Over Current

PRNDL Pseudo ignition relay driver

Buzzer Circuit

Current below normal or open circuit

 

1601-E3

 

 

33

 

 

1709

Relay

 

Transmission Controller Power

 

 

6

output Under Current Or Open Circuit

PRNDL Pseudo ignition relay driver

 

 

Current above normal or grounded circuit

 

 

1601-E3

 

33

 

1716

Relay

Retarder Selection, non-engine

 

2

output overcurrent

Transmission Retarder Level

 

Data erratic, intermittent or incorrect

 

33

 

1741

 

Level Control Mode

 

0

Selection Switch Failure

Mode Selection Switch Damaged or

 

Data Valid but Above Normal Range,            Not available

 

Not

 

33

 

1741

 

Level Control Mode

 

1

Not Connected

Possible ECU Malfunction

Most Severe

Data Valid, but Below Normal Range,            Not available

available

Not

 

33

 

1747

 

Kneeling Control Mode Request

 

2

 

Suspension Dump Switch Error

Most Severe

Faulty Switch Actuator or Microswitch for

available
 

33

 

1755

 

Lowering Control Mode Rear Axle

 

5

 

Suspension Dump Solenoid B Relay

Suspension Dump Switch

Open Circuit in Suspension Dump

Under Current Or Open Circuit Solenoid B Circuit
33

 

33

1755

 

1756

Lowering Control Mode Rear Axle

 

Lifting Control Mode Rear Axle

6

 

5

Suspension Dump Solenoid B Relay Over Current

Suspension Dump Solenoid A Relay

Short To Ground in Suspension Dump Solenoid B Circuit

Open Circuit in Suspension Dump

Under Current Or Open Circuit Solenoid A Circuit
33

 

33

1756

 

1820

Lifting Control Mode Rear Axle

 

Ramp / Wheel Chair Lift Position

6

 

5

Suspension Dump Solenoid A Relay Over Current

Wheelchair Lift Solenoid Relay

Short To Ground in Suspension Dump Solenoid A Circuit

Current below normal or open circuit

 

 

1601-E1

 

33

 

1820

 

Ramp / Wheel Chair Lift Position

 

6

Under Current Or Open Circuit

Wheelchair Lift Solenoid Relay Short

 

Current above normal or grounded circuit

 

1601-E1

To Ground

 

33 2378 Tractor Marker Light 5 Park Lights Undercurrent Open in Park Lights Circuit 1604-G
33 2378 Tractor Marker Light 6 Park Lights Overcurrent Short To Ground or Overload in Park 1604-G
Lights Circuit
33 2387 Tractor Front Fog Lights Command 2 Fog Light Switch Error Faulty Switch Actuator or Microswitch for
Fog Lights Switch
33 2388 Fog Light 1 command 5 Fog Lights Relay Under Current Or Current below normal or open circuit 1603-F
Open Circuit
33 2388 Fog Light 1 command 6 Fog Lights Relay Overcurrent Current above normal or grounded circuit 1603-F
33 2389 Rear Fog Light Command 2 Rear Fog Light Switch error Faulty Switch Actuator or Microswitch for Not available Not
Rear Fog Lights Switch available
33 2390 Rear Fog Lights 5 Rear Fog Light Relay Under Current Under Current Or Open Circuit in Rear Not available Not
Or Open Circuit Fog Light Relay Driver available
33 2390 Rear Fog Lights 6 Rear Fog Lights Relay Overcurrent Short circuit in Rear Fog Light Relay Not available Not
Driver available
33 2392 Back Up Light and Alarm Horn 5 Reverse Lights Relay Under Current Current below normal or open circuit 1601-E4
Or Open Circuit
33 2392 Back Up Light and Alarm Horn 6 Reverse Lights Relay Overcurrent Current above normal or grounded circuit 1601-E4
33 2404 Running Light 5 Running Light Control relay Under Open Circuit in Running Lights Circuit 1601-F16
Current Or Open Circuit
33 2404 Running Light 6 Running Light Control relay Over Short To Ground in Running Lights Circuit 1601-F16
Current
33 2609 Cab A/C Refrigerant Compressor 0 HVAC Pressure Sensor reading HVAC Pressure Sensor Shorted High or 1600-B12
Outlet Pressure above normal range faulty sensor system
33 2609 Cab A/C Refrigerant Compressor 1 HVAC Pressure Sensor reading HVAC Pressure Short To Ground or Open 1600-B12
Outlet Pressure below normal range Circuit or faulty sensor system
33 2609 Cab A/C Refrigerant Compressor 7 AC – Service Now. Fan At the current operating ambient
Outlet Pressure Problem/Clogged Pipe temperature the engine fan isn’t working,
one of the AC lines has become plugged
or the system is over-charged. The
compressor is shut off to prevent damage.
33 2609 Cab A/C Refrigerant Compressor 16 HVAC High Pressure Protection HVAC Head Pressure exceeded 480 psi.
Outlet Pressure Compressor shut off until next key cycle
for system protection
33 2636 Windshield Wiper Motor ON/OFF 5 Wiper On/Off Relay Under Current Open Circuit in Wiper On/Off Circuit 1601-E7
Or Open Circuit
33 2636 Windshield Wiper Motor ON/OFF 6 Wiper On/Off Relay Over Current Short To Ground in Wiper On/Off Circuit 1601-E7
33 2637 Windshield Wiper Motor Speed 5 Wiper High/Low Relay Under Current Open Circuit in Wiper High/Low Circuit 1601-E6
Or Open Circuit
33 2637 Windshield Wiper Motor Speed 6 Wiper High/Low Relay Over Current Short To Ground in Wiper High/Low 1601-E6
Circuit
33 2641 Horn 5 Electric Horn Undercurrent Open in Electric Horn Circuit 1603-E
33 2641 Horn 6 Electric Horn Overcurrent Short To Ground or Overload in City Horn 1603-E
Circuit
33 2642 Mirror Heat 1 5 Left Mirror Heat Undercurrent Open in Left Mirror Heat Circuit 1603-H
33 2642 Mirror Heat 1 6 Left Mirror Heat Overcurrent Short to Ground or Overload in Left Mirror 1603-H
Heat Circuit
33 2653 Headlamp Low Beam Left #1 5 Left Low Beam Under Current Open in Left Low Beam Circuit 1604-B
33 2653 Headlamp Low Beam Left #1 6 Left Low Beam Short To Ground Short To Ground or Overload in Left Low 1604-B
Beam Circuit
33 2655 Headlamp Low Beam Right #1 5 Right Low Beam Open Circuit Open in Right Low Beam Circuit 1604-H
33 2655 Headlamp Low Beam Right #1 6 Right Low Beam Short To Ground Short to Ground or Overload in Right Low 1604-H
Beam Circuit
33 2796 Transfer Case Selector Switch 2 Front Axle Switch Error Data erratic, intermittent or incorrect
33 2819 Park Interlock Error 5 Park Position Interlock Solenoid Current below normal or open circuit 1601-E8
Output is Under Current Or Open
Circuit.
33 2819 Park Interlock Error 6 Park Position Interlock Solenoid Current above normal or grounded circuit 1601-E8
Output is overcurrent.
33 3313 Fifth Wheel Lock Couple Status 5 Fifth Wheel Jaw Unlock Solenoid 1 Open Circuit or Defective Solenoid
Indicator output is Under Current Or Open
Circuit
33 3313 Fifth Wheel Lock Couple Status 6 Fifth Wheel Jaw Unlock Solenoid 1 Short To Ground or Defective Solenoid
Indicator output is Overcurrent
33 3314 Fifth Wheel Release Control 2 Fifth Wheel Jaw Unlock Switch state

is invalid

Data erratic, intermittent or incorrect
33 3316 Fifth Wheel Slider Lock Indicator 5 Fifth Wheel Slide Under Current Or Open Circuit in Fifth Wheel Slide Circuit
Open Circuit
33 3316 Fifth Wheel Slider Lock Indicator 6 Fifth Wheel Slide Over Current Short To Ground in Fifth Wheel Slide
Circuit
33 3412 Lock Status of Door 1 7 Driver Door Lock Motor Failure Driver Door Pod Module Has Shorted,
Opened, or Jammed Solenoid
33 3415 Lock Status of Door 2 7 Passenger Door Lock Motor Failure Passenger Door Pod Module Has
Shorted, Opened, or Jammed Solenoid
33 3418 Lock Status of Door 3 7 Rear Driver Door Lock Motor failure Rear Driver Door Pod Module Has
Shorted, Opened, or Jammed Solenoid
33 3421 Lock Status of Door 4 7 Rear Passenger Door Lock Motor Rear Passenger Door Pod Module Has
failure Shorted, Opened, or Jammed Solenoid
33 3452 Enable Switch – Transmission input 2 Transmission PTO A Switch Error Faulty Switch Actuator or Microswitch for
shaft PTO 1 Transmission PTO A Switch
33 3452 Enable Switch – Transmission input 2 PTO Engagement Switch Error Faulty Switch Actuator or Microswitch for
shaft PTO 1 Transmission PTO A Switch
33 3453 Enable Switch – Transmission input 2 Transmission PTO B Switch Error Faulty Switch Actuator or Microswitch for
shaft PTO 2 Transmission PTO B Switch
33 3455 Enable Switch – Transfer case output 2 Transfer Case Switch Error Data erratic, intermittent or incorrect
shaft PTO
33 3455 Enable Switch – Transfer case output 2 Transfer Case PTO Switch Error Data erratic, intermittent or incorrect
shaft PTO
33 3456 Engagement Consent – 5 Transmission PTO A Solenoid Relay Open Circuit in Transmission PTO A
Transmission input shaft PTO 1 Under Current Or Open Circuit Solenoid Circuit
33 3456 Engagement Consent – 6 Transmission PTO A Solenoid Relay Short To Ground in Transmission PTO A
Transmission input shaft PTO 1 Over Current Solenoid Circuit
33 3457 Engagement Consent – 5 Transmission PTO B Solenoid Relay Open Circuit in Transmission PTO B
Transmission input shaft PTO 2 Under Current Or Open Circuit Solenoid Circuit
33 3457 Engagement Consent – 6 Transmission PTO B Solenoid Relay Short To Ground in Transmission PTO B
Transmission input shaft PTO 2 Over Current Solenoid Circuit
33

 

33

3461

 

3461

Engagement Status – Transmission

input shaft PTO 2

Engagement Status – Transmission

5

 

6

PTO Air Solenoid Under Current Or

Open Circuit

PTO Air Solenoid Overcurrent

Current below normal or open circuit

 

Current above normal or grounded circuit

 

33

 

3695

input shaft PTO 2

Regen Inhibit Switch Indicator

 

2

 

Regen Inhibit Switch Error

 

Faulty Switch Actuator or Microswitch for

 

33

 

3696

 

Parked Regen Switch Indicator

 

5

 

Open Circuit in Regen Inhibit Switch

Regen Inhibit Switch

Open Circuit in the Regen Inhibit Switch

 

33

 

3696

 

Parked Regen Switch Indicator

 

6

Indicator Circuit.

Over current for Parked Regen

Indicator Circuit.

Over current or Short to Battery for the

 

33

 

3696

 

Parked Regen Switch Indicator

 

2

Switch Indicator

Parked Regen Switch Error

Parked Regen Switch Indicator.

Faulty Switch Actuator or Microswitch for

 

33

 

3697

 

Particulate Trap Lamp Command

 

5

 

Particulate Trap Lamp Relay Under

Parked Regen Switch

Open Circuit in Particulate Trap Lamp

 

33

 

3697

 

Particulate Trap Lamp Command

 

6

Current Or Open Circuit

Particulate Trap Lamp Relay Over

Circuit

Short to Ground in Particulate Trap Lamp

 

33

 

3698

 

Exhaust System High Temperature

 

5

Current

Exhaust System High Temperature

Circuit

Open Circuit in Exhaust System High

 

 

33

 

 

3698

Lamp Command

 

Exhaust System High Temperature

 

 

6

Lamp Command Under Current Or Open Circuit

Exhaust System High Temperature

Temperature Circuit

 

Short to Ground in Exhaust System High

Lamp Command Lamp Command Over Current Temperature Circuit
33 3950 Air Horn 5 Air Horn Undercurrent Open in Air Horn Circuit 1602-E12
33 3950 Air Horn 6 Air Horn Overcurrent Short To Ground or Overload in Air Horn 1602-E12
 

33

 

3952

 

Air Shield Light

 

6

 

Air Shield Lighting Overcurrent

Circuit

Short To Ground or Overload in Air Shield

 

1604-F

 

33

 

3957

 

Auxiliary Transmission Constant

 

5

 

Auxiliary Transmission Solenoid B

Light Circuit

Current below normal or open circuit

 

 

33

 

 

3957

Supply Actuator

 

Auxiliary Transmission Constant

 

 

6

(Constant Supply) output is Under Current Or Open Circuit.

Auxiliary Transmission Solenoid B

 

 

Current above normal or grounded circuit

 

 

33

 

 

3958

Supply Actuator

 

Auxiliary Transmission High Range

 

 

5

(Constant Supply) output is overcurrent.

Auxiliary Transmission Solenoid C

 

 

Current below normal or open circuit

 

 

33

 

 

3958

Actuator

 

Auxiliary Transmission High Range

 

 

6

(High) Output is Under Current Or Open Circuit.

Auxiliary Transmission Solenoid C

 

 

Current above normal or grounded circuit

 

33

 

3959

Actuator

Auxiliary Transmission Neutral

 

5

(High) output is overcurrent.

Auxiliary Transmission Solenoid A

 

Current below normal or open circuit

 

 

33

 

 

3959

Actuator

 

Auxiliary Transmission Neutral

 

 

6

(Neutral) output is Under Current Or Open Circuit.

Auxiliary Transmission Solenoid A

 

 

Current above normal or grounded circuit

 

33

 

3960

Actuator

Auxiliary Transmission Range Switch

 

2

(Neutral) output is overcurrent.

Auxiliary Transmission High/Low

 

Data erratic, intermittent or incorrect

 

33

 

3961

 

Body Equipment Hydraulic Power

 

5

Switch state is invalid.

TEM Epump Inhibit Relay Under

 

Current below normal or open circuit

 

1601-E1

 

33

 

3961

Auxiliary Pump Inhibit Command

Body Equipment Hydraulic Power

 

6

Current Or Open Circuit

TEM Epump Inhibit Relay Over

 

Current above normal or grounded circuit

 

1601-E1

 

33

 

3962

Auxiliary Pump Inhibit Command Bus Amber Signal Light 1  

5

Current

Left Front Amber PWL Undercurrent

 

Current below normal or open circuit

 

1603-C

33 3962 Bus Amber Signal Light 1 6 Left Front Amber PWL Overcurrent Current above normal or grounded circuit 1603-C
33

 

33

3963

 

3963

Bus Amber Signal Light 2

 

Bus Amber Signal Light 2

5

 

6

Right Front Amber PWL Undercurrent

Right Front Amber PWL Overcurrent

Current below normal or open circuit

 

Current above normal or grounded circuit

1604-J

 

1604-J

 

33

 

3964

 

Bus Amber Signal Light 3

 

5

 

Left Rear Amber PWL Undercurrent

 

Current below normal or open circuit

 

1603-G

 

33

 

3964

 

Bus Amber Signal Light 3

 

6

 

Left Rear Amber PWL Overcurrent

 

Current above normal or grounded circuit

 

1603-G

 

33

 

3965

 

Bus Amber Signal Light 4

 

5

 

Right Rear Amber PWL

 

Current below normal or open circuit

 

1603-K

 

33

 

3965

 

Bus Amber Signal Light 4

 

6

Undercurrent

Right Rear Amber PWL Overcurrent

 

Current above normal or grounded circuit

 

1603-K

 

33

 

3966

 

Bus Crossing Gate

 

5

 

Crossing Gate output is

 

Current below normal or open circuit

 

1602-E12

 

33

 

3966

 

Bus Crossing Gate

 

6

undercurrent.

Crossing Gate output is overcurrent.

 

Current above normal or grounded circuit

 

1602-E12

33

 

 

33

3967

 

 

3967

Bus Passenger Door Close Relay

 

 

Bus Passenger Door Close Relay

5

 

 

6

Bus Entrance Door Close Relay Driver Output is Under Current Or Open Circuit

Bus Entrance Door Close Relay

Current below normal or open circuit

 

 

Current above normal or grounded circuit

1601-E9

 

 

1601-E9

 

33

 

3969

 

Bus Passenger Door Control Switch

 

0

Driver Output is overcurrent

Bus Entrance Door Steering Wheel

 

Bus Door Control Switches Circuit Open

 

1600-B16

2 Switch Input Above Normal Range or Shorted High
33 3969 Bus Passenger Door Control Switch 2 1 Bus Entrance Door Steering Wheel Switch Input Below Normal Range Short To Ground in Bus Door Control Switches Circuit 1600-B16
33

 

 

33

3970

 

 

3970

Bus Passenger Door Open Relay

 

 

Bus Passenger Door Open Relay

5

 

 

6

Bus Entrance Door Open Relay Driver Output is Under Current Or Open Circuit

Bus Entrance Door Open Relay

Current below normal or open circuit

 

 

Current above normal or grounded circuit

1601-E13

 

 

1601-E13

 

33

 

3971

 

Bus Red Signal Light 1

 

5

Driver Output is overcurrent

Left Front Red PWL Undercurrent

 

Current below normal or open circuit

 

1603-H

33 3971 Bus Red Signal Light 1 6 Left Front Red PWL Overcurrent Current above normal or grounded circuit 1603-H
33 3972 Bus Red Signal Light 2 5 Right Front Red PWL Undercurrent Current below normal or open circuit 1603-F
33 3972 Bus Red Signal Light 2 6 Right Front Red PWL Overcurrent Current above normal or grounded circuit 1603-F
33 3973 Bus Red Signal Light 3 5 Left Rear Red PWL Undercurrent Current below normal or open circuit 1603-J
33 3973 Bus Red Signal Light 3 6 Left Rear Red PWL Overcurrent Current above normal or grounded circuit 1603-J
33 3974 Bus Red Signal Light 4 5 Right Rear Red PWL Undercurrent Current below normal or open circuit 1603-L
33 3974 Bus Red Signal Light 4 6 Right Rear Red PWL Overcurrent Current above normal or grounded circuit 1603-L
33 3975 Bus Stop Arm 5 Bus Stop Arm Output is Under Current below normal or open circuit 1601-E2
 

33

 

3975

 

Bus Stop Arm

 

6

Current Or Open Circuit

Bus Stop Arm Output is over current

 

Current above normal or grounded circuit

 

1601-E2

33 3976 Cab Dome Light 1 5 Cab Dome Light Open Circuit Open in Cab Dome Light Circuit 1604-J
33 3976 Cab Dome Light 1 6 Cab Dome Light Short To Ground Short To Ground or Overload in Cab 1604-J
Dome Light Circuit
33 3977 Cab Dome Light 2 5 Sleeper Dome Light Relay Under Open Circuit in Sleeper Dome Light 1601-F2
Current Or Open Circuit Circuit
33 3977 Cab Dome Light 2 6 Sleeper Dome Light Over Current Short To Ground in Sleeper Dome Light 1601-F2
Circuit
33 3978 Cab Dome Light 2 Switch 2 Sleeper Dome / Floor Search Light Faulty Switch Actuator or Microswitch for
Switch Error Sleeper Dome / Floor Search Light Switch
33 3979 Cab Floor Light 5 Floor Lights Relay Under Current Or Open Circuit in Floor Light Circuit 1601-E5
Open Circuit
33 3979 Cab Floor Light 6 Floor Lights Relay Over Current Short To Ground in Floor Light Circuit 1601-E5
33 3981 Cab HVAC Mode Control Actuator 2 HVAC Control Head Mode Fault HVAC Motor in Wrong Position or
DM1 Jammed
33 3982 Cab HVAC Rear Blower Speed 2 HVAC Rear Blower Speed Control Faulty Switch Actuator or Microswitch for
Control Switch Switch Error HVAC Rear Blower Speed Control Switch
33 3983 Cab HVAC Rear Temperature 2 Rear HVAC Temperature Control Faulty Switch Actuator or Microswitch for
Control Switch Switch Error Rear HVAC Temperature Control Switch
33 3984 Cab HVAC Recirculation Door 2 HVAC Control Head Air Inlet DM1 HVAC Motor in Wrong Position or
Control Actuator Jammed
33 3985 Cab HVAC System Controller 9 HVAC Control Head Circuit Failed To Abnormal update rate
Communicate With the Body
Controller
33 3987 Compression Brake Enable Switch 5 Compression Brake Indicator output Current below normal or open circuit 1601-E4
Indicator Lamp is Under Current Or Open Circuit
33 3987 Compression Brake Enable Switch 6 Compression Brake Indicator is over Current above normal or grounded circuit 1601-E4
Indicator Lamp current
33 3988 Door 1 Control Module 7 Driver Door Pod Module Failure Defective Driver Door Pod Module
33 3989 Door 1 Window Motor 7 Driver Window Motor Failure Driver Door Pod Module Window Motor
Has Short or Open or Window is Jammed
33 3990 Door 2 Control Module 7 Passenger Door Pod Module Failure Defective Passenger Door Pod Module
33 3991 Door 2 Window Motor 7 Passenger Window Motor Failure Passenger Door Pod Module Window
Motor Has Short or Open or Window is
Jammed
33 3992 Door 3 Control module 7 Rear Driver Door Pod Module Failure Defective Rear Driver Door Pod Module
33 3993 Door 3 Window Motor 7 Rear Driver Window Motor Failure Rear Driver Door Pod Module Window
Motor Has Short or Open or Window is
Jammed
33 3994 Door 4 Control Module 7 Rear Passenger Door Pod Module Defective Rear Passenger Door Pod
Failure Module
33 3995 Door 4 Window Motor 7 Rear Passenger Window Motor Rear Passenger Door Pod Module
Failure Window Motor Has Short or Open or
Window is Jammed
33 3997 Electrical Accessory Power Relay 5 Electrical Accessory Request Relay Open Circuit in Electrical Accessory 1601-E11
Under Current Or Open Circuit Request Circuit
33 3997 Electrical Accessory Power Relay 6 Electrical Accessory Request Relay Short To Ground in Electrical Accessory 1601-E11
Over Current Request Circuit
33 3998 Electrical Load Shed OFF 5 Load Shed OFF Relay Under Open Circuit in Load Shed OFF Circuit 1601-F7
Current Or Open Circuit
33 3998 Electrical Load Shed OFF 6 Load Shed OFF Relay Over Current Short To Ground in Load Shed OFF 1601-F7
Circuit
33 3999 Electrical Load Shed ON 5 Load Shed ON Relay Under Current Open Circuit in Load Shed ON Circuit 1601-F6
Or Open Circuit
33 3999 Electrical Load Shed ON 6 Load Shed ON Relay Over Current Short To Ground in Load Shed ON Circuit 1601-F6
33 4002 Engine Remote Start 6 TEM Engine Crank Relay Over Current above normal or grounded circuit
Current
33 4003 Engine Remote Stop 5 TEM Engine Stop Relay Under Current below normal or open circuit 1601-E2
Current Or Open Circuit
33 4003 Engine Remote Stop 6 TEM Engine Stop Relay Over Current above normal or grounded circuit 1601-E2
Current
33 4004 Exterior Lamp Check Switch 2 Exterior Lamp Check Switch Error Data erratic, intermittent or incorrect
33 4007 Fifth Wheel Slide Lock Switch 2 Fifth Wheel Slide Switch Error Faulty Switch Actuator or Microswitch for
Fifth Wheel Slide Switch
33 4008 Fog Light 2 5 Right Fog Light Undercurrent Open in Right Fog Light Circuit 1603-K
33 4008 Fog Light 2 6 Right Fog Light Overcurrent Short To Ground or Overload in Right Fog 1603-K
Light Output Circuit
33 4009 Fuel Filter Fuel Heater Relay 5 Fuel Heater Relay Under Current Or Open Circuit in Fuel Heater Circuit 1601-F12
Open Circuit
33 4009 Fuel Filter Fuel Heater Relay 6 Fuel Heater Relay Over Current Short To Ground in Fuel Heater Circuit 1601-F12
33 4010 Fuel Tank Transfer Pump 5 Fuel Transfer Pump Relay Under Open Circuit in Fuel Transfer Pump 1601-F11
Current Or Open Circuit Circuit
33 4010 Fuel Tank Transfer Pump 6 Fuel Transfer Pump Relay Short To Short To Ground in Fuel Transfer Pump 1601-F11
Ground Circuit
33 4011 Headlamp 1 High Beam 5 Left High Beam Open Circuit Open in Left High Beam Circuit 1604-C
33 4011 Headlamp 1 High Beam 6 Left High Beam Short To Ground Short To Ground or Overload in Left High 1604-C
Beam Circuit
33 4012 Headlamp 2 High Beam 5 Right High Beam Open Circuit Open in Right High Beam Circuit 1604-K
33 4012 Headlamp 2 High Beam 6 Right High Beam Short To Ground Short To Ground or Overload in Right 1604-K
High Beam Circuit
33 4014 High Current Auxiliary Load Switch 1 2 High Current Load Switch Error Data erratic, intermittent or incorrect
33 4016 High Current Auxiliary Power Relay 1 5 High Current Load Under Current Or Current below normal or open circuit 1601-E16
Open Circuit
33 4016 High Current Auxiliary Power Relay 1 6 High Current Load Overcurrent Current above normal or grounded circuit 1601-E16
33 4022 Lift Gate Power Control Enable 5 Lift Gate Enable Undercurrent Current below normal or open circuit 1603-J
33 4022 Lift Gate Power Control Enable 6 Lift Gate Enable Overcurrent Current above normal or grounded circuit 1603-J
33 4023 Lift Gate Power Control Switch 2 Lift Gate Switch Error Data erratic, intermittent or incorrect
33 4024 Marker Light Interrupt Switch 2 Marker Light Interrupt Switch Failure Data erratic, intermittent or incorrect

 

33 4026 Mirror Heat 2 5 Right Mirror Heat Undercurrent Open in Right Mirror Heat Circuit 1603-L
33 4026 Mirror Heat 2 6 Right Mirror Heat Overcurrent Short To Ground or Overload in Right 1603-L
Mirror Heat Circuit
33 4028 Service Brake Circuit 1 Air Tank 5 Service Brake Circuit 1 Air Tank Current below normal or open circuit
Drain Valve Drain Valve Solenoid Under Current
Or Open Circuit
33 4028 Service Brake Circuit 1 Air Tank 6 Service Brake Circuit 1 Air Tank Current above normal or grounded circuit
Drain Valve Drain Valve Solenoid Short To
Ground
33 4029 Service Brake Circuit 1 Air Tank 2 Service Brake Circuit 1 Air Tank Data erratic, intermittent or incorrect
Drain Valve Switch Drain Switch Error
33 4030 Service Brake Circuit 2 Air Tank 5 Service Brake Circuit 2 Air Tank Current below normal or open circuit
Drain Valve Drain Valve Solenoid Under Current
Or Open Circuit
33 4030 Service Brake Circuit 2 Air Tank 6 Service Brake Circuit 2 Air Tank Current above normal or grounded circuit
Drain Valve Drain Valve Solenoid Short To
Ground
33 4031 Service Brake Supply Air Tank Drain 5 Service Brake Supply Air Tank Drain Current below normal or open circuit
Valve Valve Solenoid Under Current Or
Open Circuit
33 4031 Service Brake Supply Air Tank Drain 6 Service Brake Supply Air Tank Drain Current above normal or grounded circuit
Valve Valve Solenoid Short To Ground
33 4032 Service Brake Supply Air Tank Drain 2 Service Brake Supply Air Tank Drain Data erratic, intermittent or incorrect
Valve Switch Valve Switch Error
33 4033 Sleeper Remote – Start/Stop Enable 5 Sleeper Control Enable Relay Under Current below normal or open circuit
Command Current or Open Circuit
33 4033 Sleeper Remote – Start/Stop Enable 6 Sleeper Control Enable Relay Over Short To Ground in Sleeper Control
Command Current Enable Circuit
33 4038 Snow Plow Forward Lighting Relay 2 5 Right Plow Light Relay Under Current below normal or open circuit 1601-F16
Current Or Open Circuit
33 4038 Snow Plow Forward Lighting Relay 2 6 Right Plow Light Relay Circuit Short Current above normal or grounded circuit 1601-F16
To Ground
33 4039 Snow Plow Forward Lighting Relay 1 5 Left Plow Light Relay Circuit Under Current below normal or open circuit 1601-F12
Current Or Open Circuit
33 4039 Snow Plow Forward Lighting Relay 1 6 Left Plow Light Relay Circuit Short Current above normal or grounded circuit 1601-F12
To Ground
33 4040 Snow Plow Lighting Mode Switch 2 Snow Plow Switch Error Data erratic, intermittent or incorrect
33 4041 Software Loop Time Exceeded 14 Software Loop Time Exceeded in the Software Configuration Too Big
Body Controller, Internal Fault
33 4042 Trailer Auxiliary Power Switch 2 Trailer Auxiliary Power Switch Error Faulty Switch Actuator or Microswitch for
Auxiliary Trailer Switch
33 4043 Transfer Case Front Driveline 5 Transfer Case Front Driveline Current below normal or open circuit
Actuator Solenoid Under Current Or Open
Circuit
33 4043 Transfer Case Front Driveline 6 Transfer Case Front Driveline Current above normal or grounded circuit
Actuator Solenoid Short To Ground
33 4044 Transfer Case High Range Actuator 5 Transfer Case High Range Solenoid Current below normal or open circuit
Under Current Or Open Circuit
33 4044 Transfer Case High Range Actuator 6 Transfer Case High Range Solenoid Current above normal or grounded circuit
Short To Ground
33 4045 Transfer Case Low Range Actuator 5 Transfer Case Low Range Solenoid Current below normal or open circuit
Under Current Or Open Circuit
33 4045 Transfer Case Low Range Actuator 6 Transfer Case Low Range Solenoid Current above normal or grounded circuit
Short To Ground
33 4046 Transfer Case Neutral Actuator 5 Transfer Case Neutral Solenoid Current below normal or open circuit
Under Current Or Open Circuit
33 4046 Transfer Case Neutral Actuator 6 Transfer Case Neutral Solenoid Current above normal or grounded circuit
Short To Ground
33 4047 Transfer Case Output Shaft PTO 5 Transfer Case Output Shaft PTO Current below normal or open circuit
Actuator Actuator Under Current Or Open
Circuit
33 4047 Transfer Case Output Shaft PTO 6 Transfer Case Output Shaft PTO Current above normal or grounded circuit
Actuator Actuator Over Current
33 4048 Transfer Case Range Switch 2 Transfer Case Range Switch Error Data erratic, intermittent or incorrect
33 4049 Transfer Case Rear Driveline 5 Transfer Case Rear Driveline Relay Current below normal or open circuit
Actuator Under Current Or Open Circuit
33 4049 Transfer Case Rear Driveline 6 Transfer Case Rear Driveline Relay Current above normal or grounded circuit
Actuator Over Current
33 4053 Transmission Input Shaft PTO 2 5 Transmission Input Shaft PTO Current below normal or open circuit Not available Not
Actuator Engagement Actuator Circuit Under available
Current Or Open Circuit
33 4053 Transmission Input Shaft PTO 2 6 Transmission Input Shaft PTO Current above normal or grounded circuit Not available Not
Actuator Engagement Actuator Circuit available
Overcurrent
33 4055 Transmission Retarder Enable

Switch

2 Transmission Retarder On/Off switch

Failure

Data erratic, intermittent or incorrect
33 4056 Two Speed Axle Actuator 5 Two Speed Axle Solenoid Relay Current below normal or open circuit
Under Current Or Open Circuit
33 4056 Two Speed Axle Actuator 6 Two Speed Axle Solenoid Relay Current above normal or grounded circuit
Short To Ground
33 4057 Wiper Motor 5 Wiper Motor Undercurrent Open in Wiper Motor Circuit 1604-A
33 4057 Wiper Motor 6 Wiper Motor Overcurrent Short To Ground or Overload in Wiper 1604-A
Motor Circuit
33 4058 Cab Dome Light 1 Switch 2 Cab Dome Light Switch is reporting Faulty Switch Actuator or Microswitch for
an error. Cab Dome Light Switch
33 520461 Switch 6-Pack #1 Data Link 9 Switch 6-Pack #1 Data Link Comm. Faulty Switch Pack #1 or Switch Data Link
Failure
33 520462 Switch 6-Pack #2 Data Link 9 Switch 6-Pack #2 Data Link Comm. Faulty Switch Pack #2 or Switch Data Link
Failure
33 520463 Switch 6-Pack #3 Data Link 9 Switch 6-Pack #3 Data Link Comm. Faulty Switch Pack #3 or Switch Data Link
Failure
33 520464 Electrical Accessory Request 5 Electrical Accessory Request Relay

Under Current Or Open Circuit

Open Circuit in Electrical Accessory

Request Circuit

33

 

33

520464

 

520465

Electrical Accessory Request

 

HVAC Control Head Multiple Motor

6

 

2

Electrical Accessory Request Relay Over Current

HVAC control Head Multiple Motor

Short To Ground in Electrical Accessory Request Circuit

HVAC Motor in Wrong Position or

 

33

 

520467

Faults

Comm. Loss from BC to Power Pack

 

9

Faults DM1

Comm. fault from BC to PP3.

Jammed

Private J1939 datalink problem (exceeded The Power Pack E Module has

 

 

33

 

 

520468

 

 

RPM 1 Channel 1 Cab Switch

 

 

2

 

 

RPM 1 Channel 1 Switch Error

bandwidth).                                                           stopped receiving heart beat message from the BC.

Data erratic, intermittent or incorrect

 

33

 

520469

 

RPM 1 Channel 1 Overcurrent

 

6

 

RPM 1 Channel 1 Overcurrent

 

Current above normal or grounded circuit

33 520469 RPM 1 Channel 1 Overcurrent
 

 

33

 

 

520469

 

 

RPM 1 Channel 1 Overcurrent

 

 

19

Unavailable

 

RPM 1 Channel 1 Analog Input

(PGN 65313 , Byte 3) indicates a value of

FFh

RPM 1 Channel 1 Analog Input Data

 

 

33

 

 

520470

 

 

RPM 1 Channel 2 Cab Switch

 

 

2

Invalid Data

 

RPM 1 Channel 2 Switch Error

(PGN 65313 , Byte 3) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520471

 

RPM 1 Channel 2 Overcurrent

 

6

 

RPM 1 Channel 2 Overcurrent

 

Current above normal or grounded circuit

33 520471 RPM 1 Channel 2 Overcurrent 14 RPM 1 Channel 2 Analog Input Data Unavailable RPM 1 Channel 2 Analog Input Data (PGN 65313 , Byte 4) indicates a value of FFh
33 520471 RPM 1 Channel 2 Overcurrent 19 RPM 1 Channel 2 Analog Input Invalid Data RPM 1 Channel 2 Analog Input Data (PGN 65313 , Byte 4) indicates a value in the range of FCh to FEh
33

 

33

520472

 

520473

RPM 1 Channel 3 Cab Switch

 

RPM 1 Channel 3 Overcurrent

2

 

6

RPM 1 Channel 3 Switch Error

 

RPM 1 Channel 3 Overcurrent

Data erratic, intermittent or incorrect

 

Current above normal or grounded circuit

33 520473 RPM 1 Channel 3 Overcurrent
 

 

33

 

 

520473

 

 

RPM 1 Channel 3 Overcurrent

 

 

19

Unavailable

 

RPM 1 Channel 3 Analog Input

(PGN 65313 , Byte 5) indicates a value of

FFh

RPM 1 Channel 3 Analog Input Data

 

 

33

 

 

520474

 

 

RPM 1 Channel 4 Cab Switch

 

 

2

Invalid Data

 

RPM 1 Channel 4 Switch Error

(PGN 65313 , Byte 5) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520475

 

RPM 1 Channel 4 Overcurrent

 

6

 

RPM 1 Channel 4 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520475

 

RPM 1 Channel 4 Overcurrent

 

14

 

RPM 1 Channel 4 Analog Input Data

 

RPM 1 Channel 4 Analog Input Data

 

 

33

 

 

520475

 

 

RPM 1 Channel 4 Overcurrent

 

 

19

Unavailable

 

RPM 1 Channel 4 Analog Input

(PGN 65313 , Byte 6) indicates a value of FFh

RPM 1 Channel 4 Analog Input Data

 

 

33

 

 

520476

 

 

RPM 1 Channel 5 Cab Switch

 

 

2

Invalid Data

 

RPM 1 Channel 5 Switch Error

(PGN 65313 , Byte 6) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520477

 

RPM 1 Channel 5 Overcurrent

 

6

 

RPM 1 Channel 5 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520477

 

RPM 1 Channel 5 Overcurrent

 

14

 

RPM 1 Channel 5 Analog Input Data

 

RPM 1 Channel 5 Analog Input Data

 

 

33

 

 

520477

 

 

RPM 1 Channel 5 Overcurrent

 

 

19

Unavailable

 

RPM 1 Channel 5 Analog Input

(PGN 65313 , Byte 7) indicates a value of FFh

RPM 1 Channel 5 Analog Input Data

 

 

33

 

 

520478

 

 

RPM 1 Channel 6 Cab Switch

 

 

2

Invalid Data

 

RPM 1 Channel 6 Switch Error

(PGN 65313 , Byte 7) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520479

 

RPM 1 Channel 6 Overcurrent

 

6

 

RPM 1 Channel 6 Overcurrent

 

Current above normal or grounded circuit

33 520479 RPM 1 Channel 6 Overcurrent 14 RPM 1 Channel 6 Analog Input Data Unavailable RPM 1 Channel 6 Analog Input Data (PGN 65313 , Byte 8) indicates a value of FFh
33 520479 RPM 1 Channel 6 Overcurrent 19 RPM 1 Channel 6 Analog Input Invalid Data RPM 1 Channel 6 Analog Input Data (PGN 65313 , Byte 8) indicates a value in the range of FCh to FEh
33

 

33

520480

 

520481

RPM 2 Channel 1 Cab Switch

 

RPM 2 Channel 1 Overcurrent

2

 

6

RPM 2 Channel 1 Switch Error

 

RPM 2 Channel 1 Overcurrent

Data erratic, intermittent or incorrect

 

Current above normal or grounded circuit

33 520481 RPM 2 Channel 1 Overcurrent
 

 

33

 

 

520481

 

 

RPM 2 Channel 1 Overcurrent

 

 

19

Unavailable

 

RPM 2 Channel 1 Analog Input

(PGN 65313 , Byte 3) indicates a value of

FFh

RPM 2 Channel 1 Analog Input Data

 

 

33

 

 

520482

 

 

RPM 2 Channel 2 Cab Switch

 

 

2

Invalid Data

 

RPM 2 Channel 2 Switch Error

(PGN 65313 , Byte 3) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520483

 

RPM 2 Channel 2 Overcurrent

 

6

 

RPM 2 Channel 2 Overcurrent

 

Current above normal or grounded circuit

33 520483 RPM 2 Channel 2 Overcurrent 14 RPM 2 Channel 2 Analog Input Data Unavailable RPM 2 Channel 2 Analog Input Data (PGN 65313 , Byte 4) indicates a value of FFh
33 520483 RPM 2 Channel 2 Overcurrent 19 RPM 2 Channel 2 Analog Input

Invalid Data

RPM 2 Channel 2 Analog Input Data

(PGN 65313 , Byte 4) indicates a value in the range of FCh to FEh

33 520484 RPM 2 Channel 3 Cab Switch 2 RPM 2 Channel 3 Switch Error Data erratic, intermittent or incorrect
 

33

 

520485

 

RPM 2 Channel 3 Overcurrent

 

6

 

RPM 2 Channel 3 Overcurrent

 

Current above normal or grounded circuit

33 520485 RPM 2 Channel 3 Overcurrent 14 RPM 2 Channel 3 Analog Input Data Unavailable RPM 2 Channel 3 Analog Input Data (PGN 65313 , Byte 5) indicates a value of FFh
33 520485 RPM 2 Channel 3 Overcurrent 19 RPM 2 Channel 3 Analog Input Invalid Data RPM 2 Channel 3 Analog Input Data (PGN 65313 , Byte 5) indicates a value in the range of FCh to FEh
33 520486 RPM 2 Channel 4 Cab Switch 2 RPM 2 Channel 4 Switch Error Data erratic, intermittent or incorrect
 

33

 

520487

 

RPM 2 Channel 4 Overcurrent

 

6

 

RPM 2 Channel 4 Overcurrent

 

Current above normal or grounded circuit

33 520487 RPM 2 Channel 4 Overcurrent 14 RPM 2 Channel 4 Analog Input Data Unavailable RPM 2 Channel 4 Analog Input Data (PGN 65313 , Byte 6) indicates a value of FFh
33 520487 RPM 2 Channel 4 Overcurrent 19 RPM 2 Channel 4 Analog Input Invalid Data RPM 2 Channel 4 Analog Input Data (PGN 65313 , Byte 6) indicates a value in the range of FCh to FEh
33 520488 RPM 2 Channel 5 Cab Switch 2 RPM 2 Channel 5 Switch Error Data erratic, intermittent or incorrect
 

33

 

520489

 

RPM 2 Channel 5 Overcurrent

 

6

 

RPM 2 Channel 5 Overcurrent

 

Current above normal or grounded circuit

33 520489 RPM 2 Channel 5 Overcurrent 14 RPM 2 Channel 5 Analog Input Data Unavailable RPM 2 Channel 5 Analog Input Data (PGN 65313 , Byte 7) indicates a value of FFh
33 520489 RPM 2 Channel 5 Overcurrent 19 RPM 2 Channel 5 Analog Input Invalid Data RPM 2 Channel 5 Analog Input Data (PGN 65313 , Byte 7) indicates a value in the range of FCh to FEh
33 520490 RPM 2 Channel 6 Cab Switch 2 RPM 2 Channel 6 Switch Error Data erratic, intermittent or incorrect
 

33

 

520491

 

RPM 2 Channel 6 Overcurrent

 

6

 

RPM 2 Channel 6 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520491

 

RPM 2 Channel 6 Overcurrent

 

14

 

RPM 2 Channel 6 Analog Input Data

 

RPM 2 Channel 6 Analog Input Data

 

 

33

 

 

520491

 

 

RPM 2 Channel 6 Overcurrent

 

 

19

Unavailable

 

RPM 2 Channel 6 Analog Input

(PGN 65313 , Byte 8) indicates a value of FFh

RPM 2 Channel 6 Analog Input Data

 

 

33

 

 

520504

 

 

RPM 4 Channel 1 Cab Switch

 

 

2

Invalid Data

 

RPM 4 Channel 1 Switch Error

(PGN 65313 , Byte 8) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520505

 

RPM 4 Channel 1 Overcurrent

 

6

 

RPM 4 Channel 1 Overcurrent

 

Current above normal or grounded circuit

33 520505 RPM 4 Channel 1 Overcurrent
 

 

33

 

 

520505

 

 

RPM 4 Channel 1 Overcurrent

 

 

19

Unavailable

 

RPM 4 Channel 1 Analog Input

(PGN 65313 , Byte 3) indicates a value of

FFh

RPM 4 Channel 1 Analog Input Data

 

 

33

 

 

520506

 

 

RPM 4 Channel 2 Cab Switch

 

 

2

Invalid Data

 

RPM 4 Channel 2 Switch Error

(PGN 65313 , Byte 3) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520507

 

RPM 4 Channel 2 Overcurrent

 

6

 

RPM 4 Channel 2 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520507

 

RPM 4 Channel 2 Overcurrent

 

14

 

RPM 4 Channel 2 Analog Input Data

 

RPM 4 Channel 2 Analog Input Data

 

 

33

 

 

520507

 

 

RPM 4 Channel 2 Overcurrent

 

 

19

Unavailable

 

RPM 4 Channel 2 Analog Input

(PGN 65313 , Byte 4) indicates a value of FFh

RPM 4 Channel 2 Analog Input Data

 

 

33

 

 

520508

 

 

RPM 4 Channel 3 Cab Switch

 

 

2

Invalid Data

 

RPM 4 Channel 3 Switch Error

(PGN 65313 , Byte 4) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520509

 

RPM 4 Channel 3 Overcurrent

 

6

 

RPM 4 Channel 3 Overcurrent

 

Current above normal or grounded circuit

33 520509 RPM 4 Channel 3 Overcurrent
33 520513 RPM 4 Channel 5 Overcurrent 14 RPM 4 Channel 5 Analog Input Data

Unavailable

RPM 4 Channel 5 Analog Input Data

(PGN 65313 , Byte 7) indicates a value of

 

33

 

520513

 

RPM 4 Channel 5 Overcurrent

 

19

 

RPM 4 Channel 5 Analog Input

FFh

RPM 4 Channel 5 Analog Input Data

 

 

33

 

 

520514

 

 

RPM 4 Channel 6 Cab Switch

 

 

2

Invalid Data

 

RPM 4 Channel 6 Switch Error

(PGN 65313 , Byte 7) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520515

 

RPM 4 Channel 6 Overcurrent

 

6

 

RPM 4 Channel 6 Overcurrent

 

Current above normal or grounded circuit

33 520515 RPM 4 Channel 6 Overcurrent 14 RPM 4 Channel 6 Analog Input Data Unavailable RPM 4 Channel 6 Analog Input Data (PGN 65313 , Byte 8) indicates a value of FFh
33 520515 RPM 4 Channel 6 Overcurrent 19 RPM 4 Channel 6 Analog Input Invalid Data RPM 4 Channel 6 Analog Input Data (PGN 65313 , Byte 8) indicates a value in the range of FCh to FEh
33 520540 RPM 7 Channel 1 Cab Switch 2 RPM 7 Channel 1 Switch Error Data erratic, intermittent or incorrect
 

33

 

520541

 

RPM 7 Channel 1 Overcurrent

 

6

 

RPM 7 Channel 1 Overcurrent

 

Current above normal or grounded circuit

33 520541 RPM 7 Channel 1 Overcurrent 14 RPM 7 Channel 1 Analog Input Data Unavailable RPM 7 Channel 1 Analog Input Data (PGN 65313 , Byte 3) indicates a value of FFh
33 520541 RPM 7 Channel 1 Overcurrent 19 RPM 7 Channel 1 Analog Input Invalid Data RPM 7 Channel 1 Analog Input Data (PGN 65313 , Byte 3) indicates a value in the range of FCh to FEh
33 520542 RPM 7 Channel 2 Cab Switch 2 RPM 7 Channel 2 Switch Error Data erratic, intermittent or incorrect
 

33

 

520543

 

RPM 7 Channel 2 Overcurrent

 

6

 

RPM 7 Channel 2 Overcurrent

 

Current above normal or grounded circuit

33 520543 RPM 7 Channel 2 Overcurrent 14 RPM 7 Channel 2 Analog Input Data Unavailable RPM 7 Channel 2 Analog Input Data (PGN 65313 , Byte 4) indicates a value of FFh
33 520543 RPM 7 Channel 2 Overcurrent 19 RPM 7 Channel 2 Analog Input Invalid Data RPM 7 Channel 2 Analog Input Data (PGN 65313 , Byte 4) indicates a value in the range of FCh to FEh
33 520544 RPM 7 Channel 3 Cab Switch 2 RPM 7 Channel 3 Switch Error Data erratic, intermittent or incorrect
 

33

 

520545

 

RPM 7 Channel 3 Overcurrent

 

6

 

RPM 7 Channel 3 Overcurrent

 

Current above normal or grounded circuit

33 520545 RPM 7 Channel 3 Overcurrent 14 RPM 7 Channel 3 Analog Input Data Unavailable RPM 7 Channel 3 Analog Input Data (PGN 65313 , Byte 5) indicates a value of FFh
33 520545 RPM 7 Channel 3 Overcurrent 19 RPM 7 Channel 3 Analog Input Invalid Data RPM 7 Channel 3 Analog Input Data (PGN 65313 , Byte 5) indicates a value in the range of FCh to FEh
33

 

33

520546

 

520547

RPM 7 Channel 4 Cab Switch

 

RPM 7 Channel 4 Overcurrent

2

 

6

RPM 7 Channel 4 Switch Error

 

RPM 7 Channel 4 Overcurrent

Data erratic, intermittent or incorrect

 

Current above normal or grounded circuit

33 520547 RPM 7 Channel 4 Overcurrent
 

 

33

 

 

520547

 

 

RPM 7 Channel 4 Overcurrent

 

 

19

Unavailable

 

RPM 7 Channel 4 Analog Input

(PGN 65313 , Byte 6) indicates a value of

FFh

RPM 7 Channel 4 Analog Input Data

 

 

33

 

 

520548

 

 

RPM 7 Channel 5 Cab Switch

 

 

2

Invalid Data

 

RPM 7 Channel 5 Switch Error

(PGN 65313 , Byte 6) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520549

 

RPM 7 Channel 5 Overcurrent

 

6

 

RPM 7 Channel 5 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520549

 

RPM 7 Channel 5 Overcurrent

 

14

 

RPM 7 Channel 5 Analog Input Data

 

RPM 7 Channel 5 Analog Input Data

 

 

33

 

 

520549

 

 

RPM 7 Channel 5 Overcurrent

 

 

19

Unavailable

 

RPM 7 Channel 5 Analog Input

(PGN 65313 , Byte 7) indicates a value of FFh

RPM 7 Channel 5 Analog Input Data

 

 

33

 

 

520550

 

 

RPM 7 Channel 6 Cab Switch

 

 

2

Invalid Data

 

RPM 7 Channel 6 Switch Error

(PGN 65313 , Byte 7) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

 

33

 

520551

 

RPM 7 Channel 6 Overcurrent

 

6

 

RPM 7 Channel 6 Overcurrent

 

Current above normal or grounded circuit

33 520551 RPM 7 Channel 6 Overcurrent
 

 

33

 

 

520551

 

 

RPM 7 Channel 6 Overcurrent

 

 

19

Unavailable

 

RPM 7 Channel 6 Analog Input

(PGN 65313 , Byte 8) indicates a value of

FFh

RPM 7 Channel 6 Analog Input Data

 

 

33

 

 

520552

 

 

TEM Aux 1 Int Switch

 

 

2

Invalid Data

 

TEM Aux 1 Int Switch Error

(PGN 65313 , Byte 8) indicates a value in the range of FCh to FEh

Data erratic, intermittent or incorrect

33 520553 TEM Aux 1 Switch 2 TEM Aux 1 Switch Error Data erratic, intermittent or incorrect
33

 

33

520554

 

520555

TEM Aux 1 With Interlocks Switch

 

TEM Aux 10 Switch

2

 

2

TEM Aux 1 With Interlocks Switch Error

TEM Aux 10 Switch Error

Data erratic, intermittent or incorrect

 

Data erratic, intermittent or incorrect

33 520556 TEM Aux 11 Switch 2 TEM Aux 11 Switch Error Data erratic, intermittent or incorrect
33 520557 TEM Aux 12 Switch 2 TEM Aux 12 Switch Error Data erratic, intermittent or incorrect
33 520558 TEM Aux 13 Switch 2 TEM Aux 13 Switch Error Data erratic, intermittent or incorrect
33 520559 TEM Aux 14 Switch 2 TEM Aux 14 Switch Error Data erratic, intermittent or incorrect
33 520560 TEM Aux 15 Switch 2 TEM Aux 16 Switch Error Data erratic, intermittent or incorrect
33 520561 TEM Aux 16 Switch 2 TEM Aux 16 Switch Error Data erratic, intermittent or incorrect
33 520562 TEM Aux 17 Switch 2 TEM Aux 17 Switch Error Data erratic, intermittent or incorrect
33 520563 TEM Aux 18 Switch 2 TEM Aux 18 Switch Error Data erratic, intermittent or incorrect
33 520564 TEM Aux 2 Int Switch 2 TEM Aux 2 Int Switch Error Data erratic, intermittent or incorrect
33 520565 TEM Aux 2 Switch 2 TEM Aux 2 Switch Error Data erratic, intermittent or incorrect
33

 

33

520566

 

520567

TEM Aux 2 With Interlocks Switch

 

TEM Aux 3 Int Switch

2

 

2

TEM Aux 2 With Interlocks Switch Error

TEM Aux 3 Int Switch Error

Data erratic, intermittent or incorrect

 

Data erratic, intermittent or incorrect

33 520568 TEM Aux 3 Switch 2 TEM Aux 3 Switch Error Data erratic, intermittent or incorrect
33

 

33

520569

 

520570

TEM Aux 3 With Interlocks Switch

 

TEM Aux 4 Switch

2

 

2

TEM Aux 3 With Interlocks Switch Error

TEM Aux 4 Switch Error

Data erratic, intermittent or incorrect

 

Data erratic, intermittent or incorrect

33

 

33

520571

 

520572

TEM Aux 4 With Interlocks Switch

 

TEM Aux 5 Switch

2

 

2

TEM Aux 4 With Interlocks Switch Error

TEM Aux 5 Switch Error

Data erratic, intermittent or incorrect

 

Data erratic, intermittent or incorrect

33 520573 TEM Aux 6 Switch 2 TEM Aux 6 Switch Error Data erratic, intermittent or incorrect
33 520574 TEM Aux 7 Switch 2 TEM Aux 7 Switch Error Data erratic, intermittent or incorrect
33 520575 TEM Aux 8 Switch 2 TEM Aux 8 Switch Error Data erratic, intermittent or incorrect
33 520576 TEM Aux 9 Switch 2 TEM Aux 9 Switch Error Data erratic, intermittent or incorrect
33 520577 TEM Aux Solenoid 1 5 TEM Aux Solenoid 1 Under Current Or Open Circuit Current below normal or open circuit
33 520577 TEM Aux Solenoid 1 6 TEM Aux Solenoid 1 Overcurrent Current above normal or grounded circuit
33

 

33

520578

 

520579

TEM Aux Solenoid 1 Switch

 

TEM Aux Solenoid 2

2

 

5

TEM Aux Solenoid 1 Switch Error

 

TEM Aux Solenoid 2 Under Current

Data erratic, intermittent or incorrect

 

Current below normal or open circuit

Or Open Circuit
33 520579 TEM Aux Solenoid 2 6 TEM Aux Solenoid 2 Overcurrent Current above normal or grounded circuit
33

 

33

520580

 

520581

TEM Aux Solenoid 2 Switch

 

TEM Aux Solenoid 3

2

 

5

TEM Aux Solenoid 2 Switch Error

 

TEM Aux Solenoid 3 Under Current

Data erratic, intermittent or incorrect

 

Current below normal or open circuit

Or Open Circuit
33 520581 TEM Aux Solenoid 3 6 TEM Aux Solenoid 3 Overcurrent Current above normal or grounded circuit
33

 

33

520582

 

520583

TEM Aux Solenoid 3 Switch

 

TEM Aux Solenoid 4

2

 

5

TEM Aux Solenoid 3 Switch Error

 

TEM Aux Solenoid 4 Under Current

Data erratic, intermittent or incorrect

 

Current below normal or open circuit

Or Open Circuit
33 520583 TEM Aux Solenoid 4 6 TEM Aux Solenoid 4 Overcurrent Current above normal or grounded circuit
33

 

33

520584

 

520585

TEM Aux Solenoid 4 Switch

 

TEM Aux Solenoid 5

2

 

5

TEM Aux Solenoid 4 Switch Error

 

TEM Aux Solenoid 5 Under Current

Data erratic, intermittent or incorrect

 

Current below normal or open circuit

 

33

 

520585

 

TEM Aux Solenoid 5

 

6

Or Open Circuit

TEM Aux Solenoid 5 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520586

 

TEM Aux Solenoid 5 Switch

 

2

 

TEM Aux Solenoid 5 Switch Error

 

Data erratic, intermittent or incorrect

 

33

 

520587

 

TEM Aux Solenoid 6

 

5

 

TEM Aux Solenoid 6 Under Current

 

Current below normal or open circuit

 

33

 

520587

 

TEM Aux Solenoid 6

 

6

Or Open Circuit

TEM Aux Solenoid 6 Overcurrent

 

Current above normal or grounded circuit

 

33

 

520588

 

TEM Aux Solenoid 6 Switch

 

2

 

TEM Aux Solenoid 6 Switch Error

 

Data erratic, intermittent or incorrect

 

33

 

520589

 

TEM Dual 1 Switch

 

2

 

TEM Dual 1 Switch Error

 

Data erratic, intermittent or incorrect

33

 

33

520590

 

520591

Data Link – Switch 12 Pack top

 

Data Link – Switch 12 Pack bottom

9

 

9

Switch 12-Pack Top Data Link Comm. Failure

Switch 12-Pack Bottom Data Link

Abnormal update rate

 

Abnormal update rate

 

33

 

520604

 

5V Sensor Supply

 

0

Comm. Failure

5V Sensor Supply Above Normal

 

Data valid but above normal operational

 

33

 

520604

 

5V Sensor Supply

 

1

Range

5V Sensor Supply Below Normal

range – most severe level

Data valid but below normal operational

 

33

 

520605

 

EGC Gauge Calibration

 

13

Range

Electronic Gauge Cluster checksum

range – most severe level

Defective EGC

 

33

 

520606

 

AGSP Gauge Calibration

 

13

error.

AGSP checksum error.

 

Defective AGSP

33 520607 SIC Gauge Calibration 13 SIC checksum error. Defective SIC
33

 

 

 

33

520644

 

 

 

520644

PPE3 AC Module Input Voltage

 

 

 

PPE3 AC Module Input Voltage

3

 

 

 

4

AC Module Overvoltage condition on High Voltage DC Bus.

 

 

AC Module Undervoltage condition

An Over Voltage Condition in the AC module (Inverter High Voltage Bus).

 

 

An Under Voltage Condition in the AC

A high Battery Cutout fault has occurred and the source of the fault is the AC module (inverter high voltage bus).

A low Battery Cutout fault has

 

 

 

33

 

 

 

520649

 

 

 

Air Horn Solenoid Command

 

 

 

5

on High Voltage DC Bus.

 

 

Air Horn Undercurrent

module (Inverter High Voltage Bus).

 

 

Open in Air Horn Circuit

occurred and the source of the fault is the AC module (inverter high voltage bus).
33

 

33

520649

 

520650

Air Horn Solenoid Command

 

Air Horn Switch / Headlight Interrupt

6

 

0

Air Horn Overcurrent

 

Headlight Interrupt, Marker Interrupt

Short To Ground or Overload in Air Horn Circuit

AMH Request Circuit Open or Shorted

 

 

1600-B1

 

 

33

 

 

520650

Switch

 

Air Horn Switch / Headlight Interrupt

 

 

1

and Air Horn Switch reading above normal range

Headlight Interrupt, Marker Interrupt

High

 

Short To Ground in AMH Request Circuit

 

 

1600-B1

Switch and Air Horn Switch reading below

normal range

33

 

33

520651

 

520652

Air Shield Lights Command

 

Auxiliary High Current Load Relay

6

 

5

Command
33 520652 Auxiliary High Current Load Relay 6
 

33

 

520653

Command

Auxiliary High Current Load Switch

 

2

33

 

 

33

520654

 

 

520654

Auxiliary Transmission Constant Supply Air Solenoid Command

 

Auxiliary Transmission Constant

5

 

 

6

 

 

33

 

 

520655

Supply Air Solenoid Command

 

Auxiliary Transmission High Range

 

 

5

 

 

33

 

 

520655

Air Solenoid Command

 

Auxiliary Transmission High Range

 

 

6

 

33

 

520656

Air Solenoid Command

Auxiliary Transmission Neutral Air

 

5

 

 

33

 

 

520656

Solenoid Command

 

Auxiliary Transmission Neutral Air

 

 

6

 

33

 

520657

Solenoid Command

Auxiliary Transmission Range Switch

 

2

 

33

 

520658

 

Body Equipment Hydraulic Power

 

5

 

33

 

520658

Auxiliary Pump Inhibit Command

Body Equipment Hydraulic Power

 

6

 

33

 

520659

Auxiliary Pump Inhibit Command Bus Amber Signal Light 1 Command  

5

33 520659 Bus Amber Signal Light 1 Command 6
33

 

33

520660

 

520660

Bus Amber Signal Light 2 Command

 

Bus Amber Signal Light 2 Command

5

 

6

 

33

 

520661

 

Bus Amber Signal Light 3 Command

 

5

 

33

 

520661

 

Bus Amber Signal Light 3 Command

 

6

 

33

 

520662

 

Bus Amber Signal Light 4 Command

 

5

 

33

 

520662

 

Bus Amber Signal Light 4 Command

 

6

 

33

 

520663

 

Bus Red Signal Light 4 Command

 

5

33 520663 Bus Red Signal Light 4 Command 6
33 520664 Bus Crossing Gate Command 5
 

33

 

520664

 

Bus Crossing Gate Command

 

6

33

 

 

33

520665

 

 

520665

Bus Passenger Door Close Relay Command

 

Bus Passenger Door Close Relay

5

 

 

6

 

33

 

520667

Command

Bus Passenger Door Control Switch

 

0

2
33 520667 Bus Passenger Door Control Switch 2 1
33

 

 

33

520668

 

 

520668

Bus Passenger Door Open Relay Command

 

Bus Passenger Door Open Relay

5

 

 

6

 

33

 

520669

Command

Bus Red Signal Light 1 Command

 

5

33 520669 Bus Red Signal Light 1 Command 6
33 520670 Bus Red Signal Light 2 Command 5
33 520670 Bus Red Signal Light 2 Command 6
33 520671 Bus Red Signal Light 3 Command 5
33 520671 Bus Red Signal Light 3 Command 6
33 520672 Bus Stop Arm Command 5
 

33

 

520672

 

Bus Stop Arm Command

 

6

33 520673 Cab Dome Light 1 Command 5
33 520673 Cab Dome Light 1 Command 6
 

33

 

520674

 

Cab Dome Light 1 Switch

 

2

 

33

 

520675

 

Cab Dome Light 2 Command

 

5

 

33

 

520675

 

Cab Dome Light 2 Command

 

6

 

33

 

520676

 

Cab Dome Light 2 Switch

 

2

33 520677 Cab Floor Light Command 5
 

33

 

520677

 

Cab Floor Light Command

 

6

33 520678 Cab Window Motor 1 Status 7
33

 

 

33

520679

 

 

520680

Cab Window Motor 2 Status

 

 

Cab Window Motor 3 Status

7

 

 

7

Passenger Window Motor Failure

 

 

Rear Driver Window Motor Failure

Passenger Door Pod Module Window

Motor Has Short or Open or Window is Jammed

Rear Driver Door Pod Module Window

 

 

33

 

 

520681

 

 

Cab Window Motor 4 Status

 

 

7

 

 

Rear Passenger Window Motor

Motor Has Short or Open or Window is Jammed

Rear Passenger Door Pod Module

 

 

33

 

 

520682

 

 

Compression Brake Switch Indicator

 

 

5

Failure

 

Compression Brake Indicator output

Window Motor Has Short or Open or Window is Jammed

Current below normal or open circuit

Lamp Command is Under Current Or Open Circuit
33

 

33

520682

 

520683

Compression Brake Switch Indicator Lamp Command

Door Control Module 1 Status

6

 

7

Compression Brake Indicator is over current

Driver Door Pod Module Failure

Current above normal or grounded circuit

 

Defective Driver Door Pod Module

33 520684 Door Control Module 2 Status 7 Passenger Door Pod Module Failure Defective Passenger Door Pod Module
33 520685 Door Control Module 3 Status 7 Rear Driver Door Pod Module Failure Defective Rear Driver Door Pod Module
 

33

 

520686

 

Door Control Module 4 Status

 

7

 

Rear Passenger Door Pod Module

 

Defective Rear Passenger Door Pod

 

33

 

520687

 

Engine Remote Start Command

 

5

Failure

Remote Start Relay Under Current

Module

Open Circuit in Remote Bunk Start Circuit

 

33

 

520687

 

Engine Remote Start Command

 

6

Or Open Circuit

Remote Start Relay Over Current

 

Short To Ground in Remote Bunk Start

 

33

 

520688

 

Engine Remote Stop Command

 

5

 

Remote Stop Relay Under Current

Circuit

Open Circuit in Remote Bunk Stop Circuit

 

33

 

520688

 

Engine Remote Stop Command

 

6

Or Open Circuit

Remote Stop Relay Over Current

 

Short To Ground in Remote Bunk Stop

 

33

 

520689

 

Exterior Lamp Check Switch

 

2

 

Exterior Lamp Check Switch Error

Circuit

Data erratic, intermittent or incorrect

33

 

33

520690

 

520691

Fifth Wheel Slide Latch Solenoid Command

Fog Light 2 Command

2

 

5

Fifth Wheel Slide Switch Error

 

Right Fog Light Undercurrent

Faulty Switch Actuator or Microswitch for Fifth Wheel Slide Switch

Open in Right Fog Light Circuit

33

 

33

520691

 

520692

Fog Light 2 Command

 

Fuel Transfer Pump Command

6

 

5

Right Fog Light Overcurrent

 

Fuel Transfer Pump Relay Under

Short To Ground or Overload in Right Fog Light Output Circuit

Open Circuit in Fuel Transfer Pump

 

33

 

520692

 

Fuel Transfer Pump Command

 

6

Current Or Open Circuit

Fuel Transfer Pump Relay Short To

Circuit

Short To Ground or Overload in Fuel

 

33

 

520693

 

Headlamp High Beam Command 1

 

5

Ground

Left High Beam Open Circuit

Transfer Pump Circuit

Open in Left High Beam Circuit

33

 

33

520693

 

520694

Headlamp High Beam Command 1

 

Headlamp High Beam Command 2

6

 

5

Left High Beam Short To Ground

 

Right High Beam Open Circuit

Short To Ground or Overload in Left High Beam Circuit

Open in Right High Beam Circuit

33

 

33

520694

 

520695

Headlamp High Beam Command 2

 

HVAC Mode Control Actuator

6

 

2

Right High Beam Short To Ground

 

HVAC Control Head Mode Fault

Short To Ground or Overload in Right High Beam Circuit

HVAC Motor in Wrong Position or

 

33

 

520696

 

HVAC Recirculation Door Control

 

2

DM1

HVAC Control Head Air Inlet DM1

Jammed

HVAC Motor in Wrong Position or

 

33

 

520697

Actuator

HVAC System Controller

 

9

 

HVAC Control Head Circuit Failed To

Jammed

Abnormal update rate

 

33

 

520698

 

Ignition Signal

 

2

Communicate With The BC Key State Ignition Signal Error  

Open in Ignition Signal Input Circuit To BC

33

 

33

520703

 

520703

Lift Gate Power Control Enable Command

Lift Gate Power Control Enable

5

 

6

Lift Gate Enable Undercurrent

 

Lift Gate Enable Overcurrent

Current below normal or open circuit

 

Current above normal or grounded circuit

 

33

 

520704

Command

Lift Gate Power Control Switch

 

2

 

Lift Gate Switch Error

 

Data erratic, intermittent or incorrect

33

 

33

520705

 

520705

Load Shed OFF Command

 

Load Shed OFF Command

5

 

6

Load Shed OFF Relay Under Current Or Open Circuit

Load Shed OFF Relay Over Current

Open Circuit in Load Shed OFF Circuit

 

Short To Ground in Load Shed OFF

 

33

 

520706

 

Load Shed ON Command

 

5

 

Load Shed ON Relay Under Current

Circuit

Open Circuit in Load Shed ON Circuit

 

33

 

520706

 

Load Shed ON Command

 

6

Or Open Circuit

Load Shed ON Relay Over Current

 

Short To Ground in Load Shed ON Circuit

33

 

33

520707

 

520708

Loop Time Exceeded

 

Marker Interrupt Switch

14

 

2

BC Internal Fault, Main Loop Time Exceeded

Marker Interrupt Switch Failure

Software Configuration Too Big

 

Data erratic, intermittent or incorrect

33 520709 Mirror Heat 2 Command 5 Right Mirror Heat Undercurrent Open in Right Mirror Heat Circuit
33

 

33

520709

 

520711

Mirror Heat 2 Command

 

Primary Air Tank Drain Valve

6

 

5

Right Mirror Heat Overcurrent

 

Humphrey Valve Primary Tank

Short To Ground or Overload in Right Mirror Heat Circuit

Current below normal or open circuit

 

 

33

 

 

520711

Actuator Command

 

Primary Air Tank Drain Valve

 

 

6

Solenoid Under Current Or Open Circuit

Humphrey Valve Primary Tank

 

 

Current above normal or grounded circuit

 

33

 

520712

Actuator Command

Primary Tank Drain Valve Switch

 

2

Solenoid Short To Ground

Humphrey Valve Primary Tank

 

Data erratic, intermittent or incorrect

 

33

 

520713

 

Rear HVAC Blower Speed Control

 

2

Switch Error

Rear HVAC Blower Speed Control

 

Faulty Switch Actuator or Microswitch for

Switch Switch Error Rear HVAC Blower Speed Control Switch
33 520714 Rear HVAC Temperature Control Switch 2 Rear HVAC Temperature Control Switch Error Faulty Switch Actuator or Microswitch for Rear HVAC Temperature Control Switch
33

 

 

33

520715

 

 

520715

Secondary Tank Drain Valve Actuator Command

 

Secondary Tank Drain Valve

5

 

 

6

Humphrey Valve Secondary Tank Solenoid Under Current Or Open Circuit

Humphrey Valve Secondary Tank

Current below normal or open circuit

 

 

Current above normal or grounded circuit

 

33

 

520716

Actuator Command

Secondary Tank Drain Valve Switch

 

2

Solenoid Short To Ground

Humphrey Valve Secondary Tank

 

Data erratic, intermittent or incorrect

 

33

 

520720

 

Snow Plow Light Left Forward

 

5

Switch Error

Left Plow Light Relay Under Current

 

Current below normal or open circuit

 

33

 

520720

Lighting Relay Command

Snow Plow Light Left Forward

 

6

Or Open Circuit

Left Plow Light Relay Circuit Short

 

Current above normal or grounded circuit

 

33

 

520721

Lighting Relay Command

Snow Plow Light Right Forward

 

5

To Ground

Right Plow Light Relay Under

 

Current below normal or open circuit

 

33

 

520721

Lighting Relay Command

Snow Plow Light Right Forward

 

6

Current Or Open Circuit

Right Plow Light Relay Circuit Short

 

Current above normal or grounded circuit

Lighting Relay Command To Ground
33 520722 Snow Plow Lighting Mode Switch         2 Snow Plow Switch Error Data erratic, intermittent or incorrect
33 520725 Supply Air Tank Drain Valve Actuator 5 Command Humphrey Valve Wet Tank Solenoid Under Current Or Open Circuit Current below normal or open circuit
33

 

33

520725

 

520726

Supply Air Tank Drain Valve Actuator 6 Command

Supply Air Tank Drain Valve Switch 2

Humphrey Valve Wet Tank Solenoid Short To Ground

Humphrey Valve Wet Tank Switch

Current above normal or grounded circuit

 

Data erratic, intermittent or incorrect

 

33

 

520727

Trailer Auxiliary Power Switch               2 Error

Auxiliary Switch Error

 

Faulty Switch Actuator or Micro switch for

 

33

 

520728

Trailer Left Turn Light Relay                  5  

Trailer Left Turn Lamp Relay Under

Auxiliary Trailer Switch

Open Circuit in Trailer Left Turn Lamp

 

33

 

520728

Command

Trailer Left Turn Light Relay                  6

Current Or Open Circuit

Trailer Left Turn Lamp Relay Over

Circuit

Short To Ground in Trailer Left Turn

 

33

 

520729

Command

Trailer License Plate Light Relay          5

Current

Trailer License Plate Lamp Relay

Lamp Circuit

Open Circuit in Trailer License Plate

 

33

 

520729

Command

Trailer License Plate Light Relay          6

Under Current Or Open Circuit

Trailer License Plate Lamp Relay

Lamp Circuit

Short To Ground in Trailer License Plate

 

33

 

520730

Command

Trailer Marker Light Relay Command 5

Over Current

Trailer Marker Lamp Relay Under

Lamp Circuit

Open Circuit in Trailer Marker Lamp

 

33

 

520730

 

Trailer Marker Light Relay Command 6

Current Or Open Circuit

Trailer Marker Lamp Relay Over

Circuit

Short To Ground in Trailer Marker Lamp

 

33

 

520731

Trailer Right Turn Light Relay                5 Current

Trailer Right Turn Lamp Relay Under

Circuit

Open Circuit in Trailer Right Turn Lamp

 

33

 

520731

Command

Trailer Right Turn Light Relay                6

Current Or Open Circuit

Trailer Right Turn Lamp Relay Over

Circuit

Short To Ground in Trailer Right Turn

 

33

 

520732

Command

Trailer Stop Light Relay Command 5

Current

Trailer Stop Lamp Relay Under

Lamp Circuit

Open Circuit in Trailer Stop Lamp Circuit

 

33

 

520732

 

Trailer Stop Light Relay Command 6

Current Or Open Circuit

Trailer Stop Lamp Relay Over

 

Short To Ground in Trailer Stop Lamp

 

33

 

520733

Transfer Case Blower Switch                2 Current

Transfer Case Switch Error

Circuit

Data erratic, intermittent or incorrect

 

33

 

520734

Transfer Case Front Driveline               5  

Transfer Case Solenoid D Under

 

Current below normal or open circuit

 

33

 

520734

Solenoid Command

Transfer Case Front Driveline               6

Current Or Open Circuit

Transfer Case Solenoid D Short To

 

Current above normal or grounded circuit

 

33

 

520735

Solenoid Command

Transfer Case High Range Solenoid 5

Ground

Transfer Case Solenoid C Under

 

Current below normal or open circuit

 

33

 

520735

Command

Transfer Case High Range Solenoid 6

Current Or Open Circuit

Transfer Case Solenoid C Short To

 

Current above normal or grounded circuit

 

33

 

520736

Command

Transfer Case Low Range Solenoid 5

Ground

Transfer Case Solenoid A Under

 

Current below normal or open circuit

 

33

 

520736

Command

Transfer Case Low Range Solenoid 6

Current Or Open Circuit

Transfer Case Solenoid A Short To

 

Current above normal or grounded circuit

 

33

 

520737

Command

Transfer Case Neutral Solenoid            5

Ground

Transfer Case Solenoid B Under

 

Current below normal or open circuit

 

33

 

520737

Command

Transfer Case Neutral Solenoid            6

Current Or Open Circuit

Transfer Case Solenoid B Short To

 

Current above normal or grounded circuit

 

33

 

520738

Command

Transfer Case PTO Solenoid                5

Ground

Air Solenoid B Packs Relay Under

 

Current below normal or open circuit

 

33

 

520738

Command

Transfer Case PTO Solenoid                6

Current Or Open Circuit

Air Solenoid B Packs Relay Over

 

Current above normal or grounded circuit

 

33

 

520739

Command

Transfer Case PTO Solenoid Relay 5

Current

Transfer Case PTO Solenoid Under

 

Current below normal or open circuit

 

33

 

520739

Command

Transfer Case PTO Solenoid Relay 6

Current Or Open Circuit

Transfer Case PTO Solenoid Short

 

Current above normal or grounded circuit

 

33

 

520740

Command

Transfer Case PTO Switch                    2

To Ground

Transfer Case PTO Switch Error

 

Data erratic, intermittent or incorrect

 

33

 

520741

Transfer Case Range Switch                 2  

Transfer Case Switch Error

 

Data erratic, intermittent or incorrect

33

 

33

520742

 

520742

Transfer Case Rear Driveline                5

Solenoid Command

Transfer Case Rear Driveline                6

Air Solenoid A Packs Relay Under Current Or Open Circuit

Air Solenoid A Packs Relay Over

Current below normal or open circuit

 

Current above normal or grounded circuit

 

33

 

520743

Solenoid Command

Transmission PTO Engagement          5

Current

TEM PTO Engagement Relay Under

 

Current below normal or open circuit

 

33

 

520743

Actuator Command

Transmission PTO Engagement          6

Current Or Open Circuit

TEM PTO Engagement Relay

 

Current above normal or grounded circuit

 

33

 

520744

Actuator Command

Transmission PTO Retention                5

Overcurrent

TEM PTO Retaining Solenoid

 

Current below normal or open circuit

 

33

 

520744

Actuator Command

Transmission PTO Retention                6

Undercurrent

TEM PTO Retaining Solenoid

 

Current above normal or grounded circuit

 

33

 

520745

Actuator Command

Transmission PTO Switch                      2

Overcurrent

TEM PTO Engagement Switch Error

 

Data erratic, intermittent or incorrect

 

33

 

520746

Transmission Retarder Enable              2  

Transmission Retarder On/Off switch

 

Data erratic, intermittent or incorrect

 

33

 

520747

Switch

Two Speed Axle Actuator                       5

Failure

Two Speed Axle Solenoid Relay

 

Current below normal or open circuit

 

33

 

520747

Two Speed Axle Actuator                       6 Under Current Or Open Circuit

Two Speed Axle Solenoid Relay

 

Current above normal or grounded circuit

 

33

 

520748

Wiper Motor Power                                  5 Short To Ground

Wiper Motor Undercurrent

 

Open in Wiper Motor Circuit

33

 

33

520748

 

520749

Wiper Motor Power                                  6

Mirror Heater                                             2

Wiper Motor Overcurrent

 

Mirror Heat Switch Error

Short To Ground or Overload in Wiper Motor Circuit

Faulty Switch Actuator or Microswitch for

 

33

 

520750

Fog Lights Left Command                      5  

Left Fog Light Undercurrent

Mirror Heat Switch

Open in Left Fog Light Circuit

33

 

33

520750

 

520751

Fog Lights Left Command                      6

ICON Freedomline Gear Indicator        5

Left Fog Light Overcurrent

 

ICON Freedomline Gear Indicator

Short To Ground or Overload in Left Fog Light Circuit

Open Circuit in ICON Freedomline Gear

 

 

1601-F9

 

33

 

520751

 

ICON Freedomline Gear Indicator 6

Relay Under Current

ICON Freedomline Gear Indicator

Indicator Circuit

Short To Ground in ICON Freedomline

 

1601-F9

 

33

 

520752

 

Electrical Accessory Power Switch 2

Relay Over Current

Electrical Accessory Power Switch

Gear Indicator Circuit

Faulty Switch Actuator or Microswitch for

 

33

 

520753

 

Transmission Economy Mode Switch 2

Error

Transmission Economy Mode Switch

Electrical Accessory Power Switch

Faulty Switch Actuator or Microswitch for

Error Transmission Economy Mode Switch
33

 

33

520754

 

520754

Universal Air Solenoid Relay Driver 2 5            Universal Air Solenoid Relay Driver 2 Open Circuit or Defective Solenoid Under Current Or Open Circuit

Universal Air Solenoid Relay Driver 2 6            Universal Air Solenoid Relay Driver 2 Short To Ground or Defective Solenoid

 

33

 

520755

Over Current

Universal Air Solenoid Relay Driver 3 5            Universal Air Solenoid Relay Driver 3 Open Circuit or Defective Solenoid

Under Current Or Open Circuit
33 520755 Universal Air Solenoid Relay Driver 3 6 Universal Air Solenoid Relay Driver 3 Short To Ground or Defective Solenoid
Over Current
33 520756 Universal Air Solenoid Relay Driver 4 5 Universal Air Solenoid Relay Driver 4 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520756 Universal Air Solenoid Relay Driver 4 6 Universal Air Solenoid Relay Driver 4 Short To Ground or Defective Solenoid
Over Current
33 520757 Universal Air Solenoid Relay Driver 5 5 Universal Air Solenoid Relay Driver 5 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520757 Universal Air Solenoid Relay Driver 5 6 Universal Air Solenoid Relay Driver 5 Short To Ground or Defective Solenoid
Over Current
33 520758 Universal Air Solenoid Relay Driver 6 5 Universal Air Solenoid Relay Driver 6 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520758 Universal Air Solenoid Relay Driver 6 6 Universal Air Solenoid Relay Driver 6 Short To Ground or Defective Solenoid
Over Current
33 520759 Universal Air Solenoid Relay Driver 7 5 Universal Air Solenoid Relay Driver 7 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520759 Universal Air Solenoid Relay Driver 7 6 Universal Air Solenoid Relay Driver 7 Short To Ground or Defective Solenoid
Over Current
33 520760 Universal Air Solenoid Relay Driver 8 5 Universal Air Solenoid Relay Driver 8 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520760 Universal Air Solenoid Relay Driver 8 6 Universal Air Solenoid Relay Driver 8 Short To Ground or Defective Solenoid
Over Current
33 520761 Universal Air Solenoid Relay Driver 9 5 Universal Air Solenoid Relay Driver 9 Open Circuit or Defective Solenoid
Under Current Or Open Circuit
33 520761 Universal Air Solenoid Relay Driver 9 6 Universal Air Solenoid Relay Driver 9 Short To Ground or Defective Solenoid
Over Current
33 520762 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
10 10 Under Current Or Open Circuit
33 520762 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
10 10 Over Current
33 520763 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
11 11 Under Current Or Open Circuit
33 520763 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
11 11 Over Current
33 520764 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
12 12 Under Current Or Open Circuit
33 520764 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
12 12 Over Current
33 520765 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
13 13 or Spare Relay Driver 4 Under
Current Or Open Circuit
33 520765 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
13 13 or Spare Relay Driver 4 Over
Current
33 520766 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
14 14 or Spare Relay Driver 3 Under
Current Or Open Circuit
33 520766 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
14 14 or Spare Relay Driver 3 Over
Current
33 520767 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
15 15 Under Current Or Open Circuit
33 520767 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
15 15 Over Current
33 520768 Universal Air Solenoid Relay Driver 5 Universal Air Solenoid Relay Driver Open Circuit or Defective Solenoid
16 16 Under Current Or Open Circuit
33 520768 Universal Air Solenoid Relay Driver 6 Universal Air Solenoid Relay Driver Short To Ground or Defective Solenoid
16 16 Over Current
33 520769 BUS Spare Relay Driver One 5 Spare Relay Driver One Under Open Circuit
Current Or Open Circuit
33 520769 BUS Spare Relay Driver One 6 Spare Relay Driver One Over Short To Ground
Current
33 520770 BUS Spare Relay Driver Two 5 Spare Relay Driver Two Under Open Circuit
Current Or Open Circuit
33 520770 BUS Spare Relay Driver Two 6 Spare Relay Driver Two Over Short To Ground
Current
33 520771 PPE3 AC Module Output Current 6 AC Module has shutdown due to A Surge may have occurred for a while in An Overload condition has been
overload condition. the Vehicle AC bus for a long time (The detected in the AC module and the
inverter supplies additional current to the Vehicle AC bus is shutdown.
load).
33 520772 PPE3 Fuse Open 31 PPE3 Fuse Open. Load exceeded rating.                                       PPE3 module Fuse is Open.
33 520773 PPE3 AC Module Temperature 0 AC module over temperature An overcurrent condition in the Vehicle AC An Over temperature fault has
condition. Bus might have caused an over                      occurred and the source of the fault
temperature.                                                         is the AC module (inverter high
voltage bus).
33 520774 PPE3 DC Module Temperature 0 DC module over temperature An overcurrent condition in the Vehicle DC An Over Temperature fault has
condition. Bus might have caused an over                      occurred and the source of the fault
temperature.                                                         is the DC regulator (Vehicle Battery
Bus).
33 520775 Anti Theft Ignition Relay 5 Anti Theft Ignition Relay Under Open circuit in Anti Theft Ignition Circuit 1601-E4
Current Or Open Circuit
33 520775 Anti Theft Ignition Relay 6 Anti Theft Ignition Relay over current Short to Ground in Anti Theft Ignition 1601-E4
Circuit
33 520776 Anti Theft Engine Stop Switch 2 Anti Theft Engine Stop Switch Error Faulty Switch Actuator or Microswitch for
Anti Theft Engine Stop Switch
33 520777 Anti Theft Switch 0 2 Anti Theft Switch 0 Error Faulty Switch Actuator or Microswitch for
Anti Theft Switch 0
33 520778 Anti Theft Switch 1 2 Anti Theft Switch 1 Error Faulty Switch Actuator or Microswitch for
Anti Theft Switch 1
33 520779 Anti Theft Switch 2 2 Anti Theft Switch 2 Error Faulty Switch Actuator or Microswitch for
Anti Theft Switch 2
33 520780 Anti Theft Switch 3 2 Anti Theft Switch 3 Error Faulty Switch Actuator or Microswitch for
Anti Theft Switch 3
33 520781 Anti Theft Switch 4 2 Anti Theft Switch 4 Error Faulty Switch Actuator or Microswitch for
Anti Theft Switch 4
33 520788 TEG Aux Relay Driver 1 5 TEG Aux Relay Driver Output 1 Current below normal or open circuit 1601-E16
Under Current Or Open Circuit
33 520788 TEG Aux Relay Driver 1 6 TEG Aux Relay Driver Output 1 Current above normal or grounded circuit 1601-E16
Overcurrent
33 520799 TEG Aux Relay Driver 2 5 TEG Aux Relay Driver Output 2 Current below normal or open circuit 1601-E12
Under Current Or Open Circuit
33 520799 TEG Aux Relay Driver 2 6 TEG Aux Relay Driver Output 2 Current above normal or grounded circuit 1601-E12
Overcurrent
33

 

 

33

520800

 

 

520800

Transmission Economy Mode output

 

 

Transmission Economy Mode output

5

 

 

6

Transmission Economy Mode Relay

Driver Output Under Current Or Open Circuit

Transmission Economy Mode Relay

Current below normal or open circuit

 

 

Current above normal or grounded circuit

1601-F11

 

 

1601-F11

 

33

 

520801

 

Transmission Auto Neutral Output

 

5

Driver Output Overcurrent

Transmission Auto Neutral Relay

 

Current below normal or open circuit

 

1601-E3

 

 

33

 

 

520801

 

 

Transmission Auto Neutral Output

 

 

6

Driver Output Under Current Or Open Circuit

Transmission Auto Neutral Relay

 

 

Current above normal or grounded circuit

 

 

1601-E3

 

33

 

520802

 

Aux Air Susp Solenoid Command

 

5

Driver Output Overcurrent

Aux Air Suspension Solenoid Under

 

Open Circuit or Defective Solenoid

 

1602-E12

 

33

 

520802

 

Aux Air Susp Solenoid Command

 

6

Current or Open Circuit

Aux Air Suspension Solenoid output

 

Short To Ground or Defective Solenoid

 

1602-E12

 

33

 

520803

 

Park Brake Relay Command

 

5

Over Current

Park Brake Relay Under Current or

 

Open Circuit or Defective Solenoid

 

1601-E7

 

 

33

 

 

520803

 

 

Park Brake Relay Command

 

 

6

Open Circuit

 

Park Brake Relay Over Current

 

 

Short To Ground or Defective Solenoid

1601-F1

(BUS) 1601-E7

 

 

33

 

 

520804

 

 

RKE Option Door Pod Not Present

 

 

14

 

 

Missing Remote Keyless entry door

 

 

Expected RKE door pod is not present or

 

 

Not available

1601-F1 (BUS)

Not

pod in the wrong slot or bad door pod harness available
33 520806 Fifth Wheel Jaw Unlock Sol2 Command 5 Fifth Wheel Jaw Unlock Solenoid2 output Under Current or Open Circuit Open Circuit or Defective Solenoid
33

 

33

520806

 

520807

Fifth Wheel Jaw Unlock Sol2 Command

Engine RPM Interrupt Output

6

 

5

Fifth Wheel Jaw Unlock Solenoid2 output Overcurrent

Engine RPM Interrupt Relay Driver

Short To Ground or Defective Solenoid

 

Current below normal or open circuit

 

 

1601-F3

 

 

33

 

 

520807

 

 

Engine RPM Interrupt Output

 

 

6

Output Under Current Or Open Circuit

Engine RPM Interrupt Relay Driver

 

 

Current above normal or grounded circuit

 

 

1601-F3

 

33

 

520813

 

Aux_Relay_Driver_3

 

5

Output Overcurrent

Relay Driver 3 Undercurrent

 

Open in Relay Driver 3 Circuit

 

1601-E3

33

 

33

520813

 

520814

Aux_Relay_Driver_3

 

Aux_Relay_Driver_4

6

 

5

Relay Driver 3 Overcurrent

 

Relay Driver 4 Undercurrent

Short To Ground or Overload in Relay Driver 3 Output Circuit

Open in Relay Driver 4 Circuit

1601-E3

 

1601-E4

33

 

33

520814

 

520815

Aux_Relay_Driver_4

 

Sixth Gear Disable Relay

6

 

5

Relay Driver 4 Overcurrent

 

Sixth Speed Disable Relay is

Short To Ground or Overload in Relay Driver 4 Output Circuit

Open Circuit on the Sixth Gear Disable

1601-E4

 

1601-E4

 

33

 

520815

 

Sixth Gear Disable Relay

 

6

Undercurrent or Open Circuit

Sixth Speed Disable Relay is

Relay

Short to Battery on the Sixth Speed

 

33

 

520816

 

Sixth Gear Disable LED

 

5

Overcurrent

Sixth Gear Disable LED Relay Driver

Disable Relay

Open Circuit on the Sixth Gear Disable

 

 

33

 

 

520816

 

 

Sixth Gear Disable LED

 

 

6

Output is Under Current or Open Circuit

Sixth Gear Disable LED Relay Driver

LED Relay Driver

 

Short to Battery on the Sixth Speed

 

33

 

520817

 

Sixth Gear Disable Switch

 

2

Output is Over Current

Sixth Speed Disable Switch status is

Disable LED Relay

Fault Switch Actuator or Micro switch for

 

33

 

520818

 

HEV ePTO Pressure Feedback

 

0

invalid

HEV ePTO Pressure Feedback

Sensor reading above normal range High or faulty sensor system
33

 

 

33

520818

 

 

520819

HEV ePTO Pressure Feedback

 

 

Universal Air Solenoid Relay Driver 1

1

 

 

5

HEV ePTO Pressure Feedback Sensor reading below normal range

 

Universal Air Solenoid Relay Driver 1

HEV ePTO Pressure Feedback Shorted to Ground or Open Circuit or faulty sensor system

Open Circuit or Defective Solenoid

 

33

 

520819

 

Universal Air Solenoid Relay Driver 1

 

6

Under Current Or Open Circuit

Universal Air Solenoid Relay Driver 1

 

Short To Ground or Defective Solenoid

 

33

 

520820

 

Wig-Wag Switch

 

2

Over Current

Wig-Wag Switch Error

 

Faulty Switch Actuator or Microswitch for

 

33

 

520822

 

Remote Condenser Electric Fan

 

5

 

Electric Fan A output Under Current

Wig-Wag Switch

Open Circuit in Electric Fan A output

 

Not available

 

Not

 

33

 

520822

Control A

Remote Condenser Electric Fan

 

6

or Open Circuit

Electric Fan A output Short-Circuit

 

Short circuit detected in Electric Fan A

 

Electric Fan A can be configured for

available

Not

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

520823

Control A

 

 

 

 

 

 

Remote Condenser Electric Fan

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

Electric Fan B output Under Current

output

 

 

 

 

 

 

Open Circuit in Electric Fan B output

two different outputs:

Low Side Driver RD4 – Fault is reported when Short to Battery condition is detected

High Side Driver RD31 – Fault is reported when Short to Ground condition is Detected

Not available

available

 

 

 

 

 

 

Not

 

33

 

520823

Control B

Remote Condenser Electric Fan

 

6

or Open Circuit

Electric Fan B output Short-Circuit

 

Short circuit detected in Electric Fan B

 

Electric Fan B can be configured for

available

Not

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

520839

Control B

 

 

 

 

 

 

Transfer Case Output Shaft

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

Transfer Case Output Shaft

output

 

 

 

 

 

 

Open in Odometer Shutoff Relay Circuit

two different outputs:

Low Side Driver RD7 – Fault is reported when Short to Battery condition is detected

High Side Driver RD32 – Fault is reported when Short to Ground condition is Detected

available
 

 

33

 

 

520839

Odometer Shutoff Relay

 

Transfer Case Output Shaft

 

 

6

Odometer Shutoff Relay Undercurrent

Transfer Case Output Shaft

 

 

Short or Overload in odometer Shutoff

 

 

1601-E4

Odometer Shutoff Relay Odometer Shutoff Relay Overcurrent Relay Circuit
33

 

 

33

520840

 

 

520841

Switch 12-Pack Location 7

 

 

Switch 12-Pack Location 8

13

 

 

13

Unexpected switch in 12-pack (MID

5) bottom row position 1 from left (Switch 7 of 12)

Unexpected switch in 12-pack (MID

Switch actuator installed or bad microswitch in location configured as empty

Switch actuator installed or bad

Not available

 

 

Not available

Not available

 

Not

 

 

33

 

 

520842

 

 

Switch 12-Pack Location 9

 

 

13

5) bottom row position 2 from left (Switch 8 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520843

 

 

Switch 12-Pack Location 10

 

 

13

5) bottom row position 3 from left (Switch 9 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520844

 

 

Switch 12-Pack Location 11

 

 

13

5) bottom row position 4 from left (Switch 10 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

5) bottom row position 5 from left

(Switch 11 of 12)

microswitch in location configured as

empty

available
33 520845 Switch 12-Pack Location 12 13 Unexpected switch in 12-pack (MID

5) bottom row position 6 from left (Switch 12 of 12)

Switch actuator installed or bad

microswitch in location configured as empty

Not available Not

available

33

 

 

33

520846

 

 

520847

Switch 12-Pack Location 1

 

 

Switch 12-Pack Location 2

13

 

 

13

Unexpected switch in 12-pack (MID

6) top row position 1 from left (Switch 1 of 12)

Unexpected switch in 12-pack (MID

Switch actuator installed or bad microswitch in location configured as empty

Switch actuator installed or bad

Not available

 

 

Not available

Not available

 

Not

 

 

33

 

 

520848

 

 

Switch 12-Pack Location 3

 

 

13

6) top row position 2 from left (Switch 2 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520849

 

 

Switch 12-Pack Location 4

 

 

13

6) top row position 3 from left (Switch 3 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520850

 

 

Switch 12-Pack Location 5

 

 

13

6) top row position 4 from left (Switch 4 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520851

 

 

Switch 12-Pack Location 6

 

 

13

6) top row position 5 from left (Switch 5 of 12)

Unexpected switch in 12-pack (MID

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520852

 

 

Switch 6-Pack #2 Location 1

 

 

13

6) top row position 6 from left (Switch 6 of 12)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520853

 

 

Switch 6-Pack #2 Location 2

 

 

13

(MID 7) position 1 from left (Switch 1

of 6)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520854

 

 

Switch 6-Pack #2 Location 3

 

 

13

(MID 7) position 2 from left (Switch 2

of 6)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520855

 

 

Switch 6-Pack #2 Location 4

 

 

13

(MID 7) position 3 from left (Switch 3

of 6)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520856

 

 

Switch 6-Pack #2 Location 5

 

 

13

(MID 7) position 4 from left (Switch 4

of 6)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520857

 

 

Switch 6-Pack #2 Location 6

 

 

13

(MID 7) position 5 from left (Switch 5

of 6)

Unexpected switch in switchpack 2

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520858

 

 

Switch 6-Pack #1 Location 1

 

 

13

(MID 7) position 6 from left (Switch 6

of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520859

 

 

Switch 6-Pack #1 Location 2

 

 

13

(MID 15) position 1 from left (Switch 1 of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520860

 

 

Switch 6-Pack #1 Location 3

 

 

13

(MID 15) position 2 from left (Switch 2 of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520861

 

 

Switch 6-Pack #1 Location 4

 

 

13

(MID 15) position 3 from left (Switch 3 of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520862

 

 

Switch 6-Pack #1 Location 5

 

 

13

(MID 15) position 4 from left (Switch 4 of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520863

 

 

Switch 6-Pack #1 Location 6

 

 

13

(MID 15) position 5 from left (Switch 5 of 6)

Unexpected switch in switchpack 1

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520864

 

 

Rear Axle Load Distribution Switch

 

 

2

(MID 15) position 6 from left (Switch 6 of 6)

Rear Axle Load Distribution Switch

microswitch in location configured as empty

Faulty Switch Actuator or Microswitch for

 

 

Not available

available

 

Not

 

33

 

520865

 

Rear Axle Load Distribution Solenoid

 

5

Error

Rear Axle Load Distribution A Relay

Rear Axle Load Distribution Switch

Open Circuit or Defective Solenoid

 

Not available

available

Not

A Under Current Or Open Circuit available
33

 

33

520865

 

520866

Rear Axle Load Distribution Solenoid A

Rear Axle Load Distribution Solenoid

6

 

5

Rear Axle Load Distribution A Relay Short To Ground

Rear Axle Load Distribution B Relay

Short To Ground or Defective Solenoid

 

Open Circuit or Defective Solenoid

Not available

 

Not available

Not available Not
B Under Current Or Open Circuit available
33

 

33

520866

 

520867

Rear Axle Load Distribution Solenoid B

Snow Valve Motor Relays

6

 

6

Rear Axle Load Distribution B Relay Short To Ground

Snow Valve Motor Relays Output

Short To Ground or Defective Solenoid

 

Short to Ground or Defective Relay(s)

Not available

 

Not available

Not available Not
 

33

 

520868

 

HVAC Condenser Pusher Fan Relay

 

5

Over Current

HVAC Condenser Pusher Fan

 

Open Circuit on HVAC Condenser Pusher

 

Not available

available

Not

 

 

33

 

 

520868

 

 

HVAC Condenser Pusher Fan Relay

 

 

6

Output Under Current or Open Circuit

HVAC Condenser Pusher Fan

Fan circuit

 

Short to Ground in the HVAC Condenser

 

 

Not available

available

 

Not

 

33

 

520869

 

Trailer BO Stop

 

6

Output Over Current

Trailer BO Stop Overcurrent

Pusher Fan circuit

Current above normal or grounded circuit

 

Not available

available 1601-F9
33 520870 Trailer BO Marker 6 Trailer BO Marker Overcurrent Current above normal or grounded circuit Not available 1601-E14
33 520871 BO Ignition_1 6 BO Ignition_1 Overcurrent Current above normal or grounded circuit Not available 1601-E16
33 520872 BO Ignition_2 6 BO Ignition_2 Overcurrent Current above normal or grounded circuit Not available 1601-F1
33 520873 BO Ignition_3 6 BO Ignition_3 Overcurrent Current above normal or grounded circuit Not available 1601-E1
33 520874 BO Ignition_4 6 BO Ignition_4 Overcurrent Current above normal or grounded circuit Not available 1601-E2
33

 

33

520875

 

520876

Winch IN / OUT Switch

 

Winch IN Command

2

 

5

Winch IN OUT Switch Error

 

Winch IN relay driver under current

Faulty Switch Actuator or Microswitch for Winch IN OUT Switch

Current below normal or open circuit

Not available

 

Not available

Not available Not
 

33

 

520876

 

Winch IN Command

 

6

or open circuit

Winch IN relay driver over current

 

Current above normal or grounded circuit

 

Not available

available

Not

 

33

 

520877

 

Winch OUT Command

 

5

 

Winch OUT relay driver under

 

Current below normal or open circuit

 

Not available

available

Not

 

33

 

520877

 

Winch OUT Command

 

6

current or open circuit

Winch OUT relay driver over current

 

Current above normal or grounded circuit

 

Not available

available

Not

 

33

 

520878

 

NEC Park Brake Command

 

5

 

NEC Park Brake Command is Under

 

Open Circuit or Defective Solenoid

 

Not available

available

Not

 

33

 

520878

 

NEC Park Brake Command

 

6

Current Or Open Circuit

NEC Park Brake Command is

 

Short To Ground or Defective Solenoid

 

Not available

available

Not

overcurrent available
33

 

33

520879

 

520879

NEC Service Door Command                5

NEC Service Door Command                6

NEC Service Door Command is            Open Circuit or Defective Solenoid                  Not available

Under Current Or Open Circuit

NEC Service Door Command is            Short To Ground or Defective Solenoid Not available

Not

available Not

 

33

 

520880

 

NEC Post Trip Inspection Command 5

overcurrent

NEC Post Trip Inspection Command  Open Circuit or Defective Solenoid                  Not available

available

Not

is Under Current Or Open Circuit available
33

 

33

520880

 

520881

NEC Post Trip Inspection Command 6

TEM Interlocked Switch Relay 1           5

NEC Post Trip Inspection Command  Short To Ground or Defective Solenoid  Not available is overcurrent

TEM Switch Interlocked Output              Open circuit in TEM Interlocked circuit 1 Not available

Not available Not
 

33

 

520881

TEM Interlocked Switch Relay 1           6 Circuit 1 undercurrent

TEM Switch Interlocked Output              Short circuit in TEM Interlocked circuit 1 Not available

available

Not

 

33

 

520882

TEM Interlocked Switch Relay 2           5 Circuit 1 overcurrent

TEM Switch Interlocked Output              Open circuit in TEM Interlocked circuit 2 Not available

available

Not

 

33

 

520882

TEM Interlocked Switch Relay 2           6 Circuit 2 undercurrent

TEM Switch Interlocked Output              Short circuit in TEM Interlocked circuit 2 Not available

available

Not

 

33

 

520883

Transfer Case Low Indicator                  5 Circuit 2 overcurrent

Transfer case low indicator high side Not available                                                         Not available

available

1601-F7

 

 

33

 

 

520883

Transfer Case Low Indicator                  6 output exhibits an undercurrent condition or is open

Transfer case low indicator high side Not available                                                         Not available

 

 

1601-F7

 

 

33

 

 

520884

Transfer Case Neutral Indicator            5 output exhibits an overcurrent condition or is short to ground

Transfer case neutral indicator high  Not available                                                         Not available

 

 

1601-F6

 

 

33

 

 

520884

Transfer Case Neutral Indicator            6 side output exhibits an undercurrent condition or is open

Transfer case neutral indicator high  Not available                                                         Not available

 

 

1601-F6

side output exhibits an overcurrent condition or is short to ground
33

 

33

520885

 

520885

Windshield Heat Left Output                  5

Windshield Heat Left Output                  6

Windshield Heat Left output Under    Open Circuit in Windshield Heat Left              Not available Current or Open Circuit          Output

Windshield Heat Left Output Short- Short Circuit detected in Windshield Heat Not available

Not available Not
 

33

 

520886

Windshield Heat Right Output               5 Circuit                                                          Left Output

Windshield Heat Right Output Under Open Circuit detected in Windshield Heat Not available

available

Not

 

33

 

520886

Windshield Heat Right Output               6 Current or Open Circuit                           Right Output

Windshield Heat Right Output Short- Short Circuit detected in Windshield Heat Not available

available

Not

 

33

 

520887

 

Windshield Heat Left Temp Sensor 0

Circuit                                                          Right Output

Left Windshield Heat Temperature Left Windshield Heat Temperature Sensor Not available

available

Not

 

 

33

 

 

520887

 

 

Windshield Heat Left Temp Sensor 1

Sensor reading above normal range Shorted High or Open Circuit or faulty

sensor system

Left Windshield Heat Temperature Left Windshield Heat Temperature Sensor Not available

available

 

Not

Sensor reading below normal range Short to Ground or faulty sensor system available
33

 

 

33

520888

 

 

520888

Windshield Heat Right Temp Sensor 0

 

 

Windshield Heat Right Temp Sensor 1

Right Windshield Heat Temperature  Right Windshield Heat Temperature               Not available Sensor reading above normal range Sensor Shorted High or Open Circuit or

faulty sensor system

Right Windshield Heat Temperature  Right Windshield Heat Temperature               Not available

Not available

 

Not

 

 

33

 

 

520889

Relay Driver 9, Channel 1                       13 Sensor reading below normal range Sensor Short to Ground or faulty sensor

system

Connector J4 Pin E11 has a load on Connector J4 Pin E11 is drawing current Not available

available

 

Not

this pin that has been configured as and it is configured as unused check unused                                             configuration and or wiring harness available
33 520890 Relay Driver 10, Channel 2                     13 Connector J4 Pin E10 has a load on Connector J4 Pin E10 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33 520891 Relay Driver 11, Channel 3                     13 Connector J4 Pin E15 has a load on Connector J4 Pin E15 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33 520892 Relay Driver 12, Channel 4                     13 Connector J4 Pin E14 has a load on Connector J4 Pin E14 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33 520893 Relay Driver 13, Channel 5                     13 Connector J4 Pin E16 has a load on Connector J4 Pin E16 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33 520894 Relay Driver 14, Channel 6                     13 Connector J4 Pin E12 has a load on Connector J4 Pin E12 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33 520895 Relay Driver 15, Channel 7                     13 Connector J4 Pin E13 has a load on Connector J4 Pin E13 is drawing current Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Not available
33

 

 

33

520896

 

 

520897

Relay Driver 16, Channel 8                     13

Relay Driver 17, Channel 9                     13

Connector J4 Pin E9 has a load on Connector J4 Pin E9 is drawing current  Not available this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

Connector J4 Pin F6 has a load on Connector J4 Pin F6 is drawing current Not available

Not available

 

Not

 

 

33

 

 

520898

Relay Driver 18, Channel 10                  13 this pin that has been configured as and it is configured as unused check unused                                             configuration and or wiring harness

Connector J4 Pin F7 has a load on Connector J4 Pin F7 is drawing current Not available

available

 

Not

 

 

33

 

 

520899

Relay Driver 19, Channel 11                  13 this pin that has been configured as and it is configured as unused check unused                                             configuration and or wiring harness

Connector J4 Pin F2 has a load on Connector J4 Pin F2 is drawing current Not available

available

 

Not

 

 

33

 

 

520900

Relay Driver 20, Channel 12                  13 this pin that has been configured as and it is configured as unused check unused                                             configuration and or wiring harness

Connector J4 Pin F3 has a load on Connector J4 Pin F3 is drawing current Not available

available

 

Not

 

 

33

 

 

520901

Relay Driver 21, Channel 13                  13 this pin that has been configured as and it is configured as unused check unused                                             configuration and or wiring harness

Connector J4 Pin F1 has a load on Connector J4 Pin F1 is drawing current Not available

available

 

Not

this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

available
33

 

 

33

520902

 

 

520903

Relay Driver 22, Channel 14                  13

Relay Driver 23, Channel 15                  13

Connector J4 Pin F5 has a load on Connector J4 Pin F5 has a load on this pin Not available this pin that has been configured as that has been configured as unused

unused

Connector J4 Pin F4 has a load on Connector J4 Pin F4 is drawing current Not available

Not available

 

Not

this pin that has been configured as and it is configured as unused check

unused                                                         configuration and or wiring harness

available
33

 

 

33

520904

 

 

520905

Relay Driver 24, Channel 16

 

 

Relay Driver 25, Channel 17

13

 

 

13

Connector J4 Pin F8 has a load on

this pin that has been configured as unused

Connector J4 Pin F10 has a load on

Connector J4 Pin F8 is drawing current

and it is configured as unused check configuration and or wiring harness Connector J4 Pin F10 is drawing current

Not available

 

 

Not available

Not

available

 

Not

this pin that has been configured as unused and it is configured as unused check configuration and or wiring harness available
33 520906 Relay Driver 26, Channel 18 13 Connector J4 Pin F11 has a load on this pin that has been configured as unused Connector J4 Pin F11 is drawing current and it is configured as unused check configuration and or wiring harness Not available Not available
33 520907 Relay Driver 27, Channel 19 13 Connector J4 Pin F14 has a load on this pin that has been configured as unused Connector J4 Pin F14 is drawing current and it is configured as unused check configuration and or wiring harness Not available Not available
33 520908 Relay Driver 28, Channel 20 13 Connector J4 Pin F15 has a load on this pin that has been configured as unused Connector J4 Pin F15 is drawing current and it is configured as unused check configuration and or wiring harness Not available Not available
33 520909 Relay Driver 29, Channel 21 13 Connector J4 Pin F13 has a load on this pin that has been configured as unused Connector J4 Pin F13 is drawing current and it is configured as unused check configuration and or wiring harness Not available Not available
33

 

 

33

520910

 

 

520911

Relay Driver 30, Channel 22

 

 

Relay Driver 31, Channel 23

13

 

 

13

Connector J4 Pin F9 has a load on this pin that has been configured as unused

Connector J4 Pin F16 has a load on

Connector J4 Pin F9 is drawing current and it is configured as unused check configuration and or wiring harness Connector J4 Pin F16 is drawing current Not available

 

 

Not available

Not available

 

Not

this pin that has been configured as unused and it is configured as unused check configuration and or wiring harness available
33 520912 Relay Driver 32, Channel 24 13 Connector J4 Pin F12 has a load on this pin that has been configured as unused Connector J4 Pin F12 is drawing current and it is configured as unused check configuration and or wiring harness Not available Not available
33

 

 

33

520913

 

 

520914

Relay Driver 1, Channel 25

 

 

Relay Driver 2, Channel 26

13

 

 

13

Connector J4 Pin E7 has a load on this pin that has been configured as unused

Connector J4 Pin E6 has a load on

Connector J4 Pin E7 is drawing current and it is configured as unused check configuration and or wiring harness Connector J4 Pin E6 is drawing current Not available

 

 

Not available

Not available

 

Not

 

 

33

 

 

520915

 

 

Relay Driver 3, Channel 27

 

 

13

this pin that has been configured as unused

Connector J4 Pin E3 has a load on

and it is configured as unused check

configuration and or wiring harness Connector J4 Pin E3 is drawing current

 

 

Not available

available

 

Not

 

 

33

 

 

520916

 

 

Relay Driver 4, Channel 28

 

 

13

this pin that has been configured as unused

Connector J4 Pin E2 has a load on

and it is configured as unused check

configuration and or wiring harness Connector J4 Pin E2 is drawing current

 

 

Not available

available

 

Not

 

 

33

 

 

520917

 

 

Relay Driver 5, Channel 29

 

 

13

this pin that has been configured as unused

Connector J4 Pin E4 has a load on

and it is configured as unused check

configuration and or wiring harness Connector J4 Pin E4 is drawing current

 

 

Not available

available

 

Not

 

 

33

 

 

520918

 

 

Relay Driver 6, Channel 30

 

 

13

this pin that has been configured as unused

Connector J4 Pin E8 has a load on

and it is configured as unused check

configuration and or wiring harness Connector J4 Pin E8 is drawing current

 

 

Not available

available

 

Not

this pin that has been configured as

unused

and it is configured as unused check

configuration and or wiring harness

available
33

 

 

33

520919

 

 

520920

Relay Driver 7, Channel 31

 

 

Relay Driver 8, Channel 32

13

 

 

13

Connector J4 Pin E1 has a load on this pin that has been configured as unused

Connector J4 Pin E5 has a load on

Connector J4 Pin E1 is drawing current and it is configured as unused check configuration and or wiring harness

Connector J4 Pin E5 is drawing current

Not available

 

 

Not available

Not available

 

Not

 

 

33

 

 

520922

 

 

Switch 6-Pack #3 Location 1

 

 

13

this pin that has been configured as unused

Unexpected switch in switchpack 3

and it is configured as unused check

configuration and or wiring harness Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520923

 

 

Switch 6-Pack #3 Location 2

 

 

13

(MID 3) position 1 from left (Switch 1

of 6)

Unexpected switch in switchpack 3

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520924

 

 

Switch 6-Pack #3 Location 3

 

 

13

(MID 3) position 2 from left (Switch 2

of 6)

Unexpected switch in switchpack 3

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520925

 

 

Switch 6-Pack #3 Location 4

 

 

13

(MID 3) position 3 from left (Switch 3

of 6)

Unexpected switch in switchpack 3

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520926

 

 

Switch 6-Pack #3 Location 5

 

 

13

(MID 3) position 4 from left (Switch 4

of 6)

Unexpected switch in switchpack 3

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520927

 

 

Switch 6-Pack #3 Location 6

 

 

13

(MID 3) position 5 from left (Switch 5

of 6)

Unexpected switch in switchpack 3

microswitch in location configured as empty

Switch actuator installed or bad

 

 

Not available

available

 

Not

 

 

33

 

 

520928

 

 

Daytime Running Light Tell Tale

 

 

5

(MID 3) position 6 from left (Switch 6

of 6)

DRL Tell Tale Relay Command is

microswitch in location configured as empty

Open Circuit or Defective Solenoid

 

 

Not available

available

 

Not

 

33

 

520928

Command

Daytime Running Light Tell Tale

 

6

Under Current Or Open Circuit

DRL Tell Tale Relay Command is

 

Short To Ground or Defective Solenoid

 

Not available

available

Not

 

58

 

109

Command

Coolant Pressure

 

14

Overcurrent

High Refrigerant Pressure

 

High refrigerant pressure in system or

available
 

 

58

 

 

168

 

 

Electrical Potential (Voltage)

 

 

3

 

 

Battery Voltage High

pressure sensor unplugged or faulty Pressure sensor

Battery voltage above 16VDC

58 168 Electrical Potential (Voltage) 4 Battery Voltage Low Battery voltage below 12.1VDC
58

 

 

58

1547

 

 

1547

A/C Evaporator Temperature

 

 

A/C Evaporator Temperature

0

 

 

1

Duct Inlet Sensor High

 

 

Duct Inlet sensor Low

Recirc sensor wire shorted to power or Recirc sensor missing or open circuit or faulty Recirc sensor

Recirc sensor wire shorted to ground or

 

58

 

1548

 

HVAC Duct Temperature

 

3

 

Duct temperature sensor voltage

fault Recirc sensor

Duct temperature sensor wire shorted to

high power or open circuit or faulty sensor